FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Automation Controllers MELSEC
FAQ
Keyword Search
Programmable Automation Controllers MELSEC
FAQ within [ Programmable Automation Controllers MELSEC ]
-
Regarding the default IP address
The MX-F Model has two built-in Ethernet ports. In the following, the Ethernet port (P1) is referred to as P1 and the Ethernet port (P2) as P2. *P2 selects... More Details >>
- No:44981
- Release Date:2025/05/08 09:02
- Category: MELSEC MX Controller MX-F Model
-
Regarding how to check the date of manufacture
You can check the LOT. on the front of the controller or the nameplate on the right side. Verifying on the front of the Controller Nameplate verification... More Details >>
- No:44968
- Release Date:2025/05/08 09:05
- Category: MELSEC MX Controller MX-F Model
-
Regarding iQ-F Series Project Conversion
It's possible. In GX Works3, select [Project] → [Change Module Type/Operation Mode], and select the Series: MX controller, Type/Model: MXF100, Number of Axes... More Details >>
- No:44987
- Release Date:2025/05/08 09:09
- Category: MELSEC MX Controller MX-F Model
-
Regarding built-in high-speed counter function
The MX-F Model also supports the built-in high-speed counter function. The number of channels is up to 8, and the counter types supported are 1-phase 1-inpu... More Details >>
- No:44980
- Release Date:2025/05/08 09:08
- Category: MELSEC MX Controller MX-F Model
-
Regarding number of connectable expansion modules
Up to 16 expansion modules can be connected. However, up to 15 intelligent modules can be connected. More Details >>
- No:44967
- Release Date:2025/05/08 09:06
- Category: MELSEC MX Controller MX-F Model
-
Regarding Always-On Special Relay Numbers
It is SM400. More Details >>
- No:44986
- Release Date:2025/05/08 09:08
- Category: MELSEC MX Controller MX-F Model
-
Regarding number of internal Ethernet port connections
The Ethernet port (P2) has 32 connections. The breakdown is as follows: total of MELSOFT connections, SLMP, and socket communications ≦ 32 connections. Apa... More Details >>
- No:44974
- Release Date:2025/05/08 09:07
- Category: MELSEC MX Controller MX-F Model
-
Regarding built-in ethernet port differences
Port 1 becomes the CC-Link IE TSN, and port 2 can be switched between Ethernet and CC-Link IE TSN. To use port 2 as an Ethernet port, set the Built-in Netwo... More Details >>
- No:44969
- Release Date:2025/05/08 09:05
- Category: MELSEC MX Controller MX-F Model
-
Regarding supported programming languages
The following programming languages are supported. ・Ladder diagram (LD) ・Structured text (ST) ・Function block diagram (FBD/LD) More Details >>
- No:44972
- Release Date:2025/05/08 09:06
- Category: MELSEC MX Controller MX-F Model
-
Regarding connectable Intelligent Function modules
The MX-F Model can be connected to the intelligent function modules of the iQ-F series. Connectable intelligent function modules are shown below. More Details >>
- No:44983
- Release Date:2025/05/08 09:06
- Update:2025/11/05 08:05
- Category: MELSEC MX Controller MX-F Model
1-10 of Total 28