FAQ


FAQAbout Products
- FAQ > Controllers > Motion Controllers > MELSEC-Q Series > Motion Controllers > Q17nDCPU
FAQ
Keyword Search
FAQ within [ Q17nDCPU ]
-
Acceleration/deceleration time change
No, the time cannot be changed during operation. (Note): The following is the modules that support the acceleration/deceleration change function. • Q17nDSCP... More Details >>
- No:23570
- Release Date:2018/09/14 15:09
-
PCPU READY complete flag (SM500)
The PCPU READY complete flag (SM500) turns ON when no error is detected in the fixed parameters, servo parameters, and limit switch output data, which are ch... More Details >>
- No:23564
- Release Date:2018/09/14 15:09
-
Because the rapid stop deceleration time is larger than the deceleration time.Set the rapid stop deceleration time within the range of 1 to the deceleration ... More Details >>
- No:23550
- Release Date:2018/09/14 15:09
-
Yes, they are included.In addition, a battery (Q6BAT) is also included. More Details >>
- No:23576
- Release Date:2018/09/14 15:09
-
Specify the target axes during operation, and execute the following speed change request instruction. (1) Motion SFC program/Motion program Speed change requ... More Details >>
- No:23573
- Release Date:2018/09/14 15:09
-
Check the following signals. • Start accept flag (M2001 to M2032) • Positioning start complete signal (M4000+20n (n: Axis No.-1)) More Details >>
- No:23552
- Release Date:2018/09/14 15:09
- Update:2023/02/08 10:39
-
Servo motor rotation direction
To reflect the change, set "[PA14] Rotation direction selection/traveldirection selection" and cycle the servo amplifier or execute a home position return af... More Details >>
- No:23579
- Release Date:2018/09/14 15:09
-
No, there is no impact on the command speed.However, the actual acceleration/deceleration time are affected by the change. More Details >>
- No:23556
- Release Date:2018/09/14 15:09
-
Minor error 120 occurs in the following case:The zero pass signal (M2406+20n) is OFF when the re-movement to the home position is performed by proximity dog,... More Details >>
- No:23559
- Release Date:2018/09/14 15:09
-
Both OUT and SET instructions set the device by completion of condition.However, if not completion of condition, OUT instruction resets the device while SET ... More Details >>
- No:23553
- Release Date:2018/09/14 15:09
1-10 of Total 20