CUP type of stand-alone Motion contro...
The following shows the specification for the PLC CPU area. Q170MSCPU: Equivalent to PLC CPU "Q03UDCPU" • Program capacity: 30k steps • LD instruction proces... More Details >>
Both OUT and SET instructions set the device by completion of condition.However, if not completion of condition, OUT instruction resets the device while SET ... More Details >>
Change the direction with "[PA14] Rotation direction selection/travel direction selection". More Details >>
Minor error 120 occurs in the following case:The zero pass signal (M2406+20n) is OFF when the re-movement to the home position is performed by proximity dog,... More Details >>
Specify the target axes during operation, and execute the following speed change request instruction. (1) Motion SFC program Speed change request CHGV, CHGVS... More Details >>
Because the rapid stop deceleration time is larger than the deceleration time.Set the rapid stop deceleration time within the range of 1 to the deceleration ... More Details >>
Acceleration/deceleration time change
Yes, the time can be changed during operation by using the acceleration/deceleration time change function. Set the acceleration/deceleration time change para... More Details >>
Error 2035 (Command frequency error) occurs when the servo amplifier detects a command frequency error. (1) When the command is the permissible speed or high... More Details >>
Check the following signals.• Start accept flag (M2001 to M2032)• Positioning start complete signal (M4000+20n (n: Axis No.-1)) More Details >>
PCPU READY complete flag (SM500)
The PCPU READY complete flag (SM500) turns ON when no error is detected in the fixed parameters, servo parameters, and limit switch output data, which are ch... More Details >>