  • Inching operation

    Set "[Cd.16] Inching movement amount", and turn ON the Forward run JOG start signal or the Reverse run JOG start signal. More Details >>

    • No:23590
    • Release Date:2018/09/14 15:09
  • Positioning start

    There are two ways to start a positioning operation: (1) Set the "[Cd.3] Positioning start No.", and turn ON the positioning start signal. (2) Use the dedica... More Details >>

    • No:23593
    • Release Date:2018/09/14 15:09
  • Input/output signal

    Check if 24 VDC power is supplied to "1A7" (pin No.) of the external input signal connector. More Details >>

    • No:23594
    • Release Date:2018/09/14 15:09
  • Positioning start No.

    The following shows the setting value details.• 1 to 600: Positioning data No.• 7000 to 7004: Block start designation• 9001: Machine home position return• 90... More Details >>

    • No:23597
    • Release Date:2018/09/14 15:09
  • Error 1205

    Error 1205 (SSCNET communication error) occurs when erroneous data is received from servo amplifier. [When the servo parameter "[PA14] Rotation direction se... More Details >>

    • No:23614
    • Release Date:2018/09/14 15:09
  • Axis error reset

    It depends on the servo error.Some can be cleared by "[Cd.5] Axis error reset" but the other cannot unless the servo amplifier's power is turned OFF.Refer to... More Details >>

    • No:23584
    • Release Date:2018/09/14 15:09
  • Servo status

    Yes. You can check the servo status through the following monitor data.• "[Md.108] Servo status"• "[Md.125] Servo status 3"• "[Md.500] Servo status 7" More Details >>

    • No:23588
    • Release Date:2018/09/14 15:09
  • Speed limit value

    No, there is no impact on the command speed.However, the actual acceleration/deceleration time are affected by the change. More Details >>

    • No:23595
    • Release Date:2018/09/14 15:09
  • Alarm E7

    Alarm E7 (Controller forced stop warning) occurs when an forced stop is executed by the Positioning module or the Simple Motion module. The following shows h... More Details >>

    • No:23607
    • Release Date:2018/09/14 15:09
  • HPR request flag

    It depends on the setting of servo parameter "[PA03] Absolute position detection system" whether the HPR request flag ("[Md.31] Status": b3) turns ON or not.... More Details >>

    • No:23617
    • Release Date:2018/09/14 15:09