  • Torque limit

    Set the torque limit value in "[Cd.101] Torque output setting value" before the positioning start.The values of "[Pr.17] Torque limit setting value" and "[Cd... More Details >>

    • No:23583
    • Release Date:2018/09/14 15:09
  • JOG speed

    Set "[Cd.17] JOG speed" before starting the operation.When changing the speed during the operation, change it to the new speed with the speed change function. More Details >>

    • No:23581
    • Release Date:2018/09/14 15:09
  • Command in-position

    Refer to "b2: Command in-position flag" of "[Md.31] Status". More Details >>

    • No:23598
    • Release Date:2018/09/14 15:09
  • HPR request flag

    It depends on the setting of servo parameter "[PA03] Absolute position detection system" whether the HPR request flag ("[Md.31] Status": b3) turns ON or not.... More Details >>

    • No:23617
    • Release Date:2018/09/14 15:09
  • Error 1205

    Error 1205 (SSCNET communication error) occurs when erroneous data is received from servo amplifier. [When the servo parameter "[PA14] Rotation direction se... More Details >>

    • No:23614
    • Release Date:2018/09/14 15:09
  • Input/output signal

    Check if 24 VDC power is supplied to "1A7" (pin No.) of the external input signal connector. More Details >>

    • No:23594
    • Release Date:2018/09/14 15:09
  • Restart

    Set "[Cd.6] Restart command" to "1". More Details >>

    • No:23619
    • Release Date:2018/09/14 15:09
  • Speed change during JOG operation

    Yes. The speed can be changed during JOG operation.Set the new speed with "[Cd.14] New speed value", and then set "[Cd.15] Speed change request" to "1". More Details >>

    • No:23606
    • Release Date:2018/09/14 15:09
  • Inching operation

    Set "[Cd.16] Inching movement amount", and turn ON the Forward run JOG start signal or the Reverse run JOG start signal. More Details >>

    • No:23590
    • Release Date:2018/09/14 15:09
  • Degree axis

    Yes. (1) Absolute system (a) When the software stroke limit is invalid Positioning is carried out in a designated direction by "[Cd.40] ABS direction in deg... More Details >>