FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Automation Controllers MELSEC > MELSEC MX Controller MX-F Model
FAQ
Keyword Search
FAQ within [ MELSEC MX Controller MX-F Model ]
-
Regarding the default IP address
The MX-F Model has two built-in Ethernet ports. In the following, the Ethernet port (P1) is referred to as P1 and the Ethernet port (P2) as P2. *P2 selects... More Details >>
- No:44981
- Release Date:2025/05/08 09:02
-
Regarding maximum number of input/output points
The maximum number of input/output points is 512. The number of remote I/O points is not limited, but can be used within the specification range of each int... More Details >>
- No:44971
- Release Date:2025/05/08 09:07
-
Regarding the Program List Monitor
On the MX-F Model, the Performance Monitor function enables Program List Monitor. The operation cycle and load status of the core can be visualized. More Details >>
- No:44989
- Release Date:2025/05/08 09:08
-
Regarding number of expansion adapter connections
The number of expansion adapters varies depending on the type of adapter, and up to six can be connected. ・Analog adapter: Up to 4 ・Communication adapter: ... More Details >>
- No:44966
- Release Date:2025/05/08 09:05
-
Regarding supported programming languages
The following programming languages are supported. ・Ladder diagram (LD) ・Structured text (ST) ・Function block diagram (FBD/LD) More Details >>
- No:44972
- Release Date:2025/05/08 09:06
-
Regarding number of internal Ethernet port connections
The Ethernet port (P2) has 32 connections. The breakdown is as follows: total of MELSOFT connections, SLMP, and socket communications ≦ 32 connections. Apa... More Details >>
- No:44974
- Release Date:2025/05/08 09:07
-
Regarding the built-in motion function
The built-in motion function of the MX-F Model is programmed using motion control FB, wheareas the FX5-40/80SSC-G of the iQ-F series is programmed using buff... More Details >>
- No:44970
- Release Date:2025/06/18 14:38
-
Regarding use of extended extension cable
Extended extension cable for MX-F Model: FX5-30 EC/FX5-65 EC can be used. However, only one extended extension cable is allowed per system. *Extended extens... More Details >>
- No:44985
- Release Date:2025/05/08 09:07
-
Regarding Intelligent Function Modules with connectivity constraints
The following intelligent function modules have restrictions on the number of modules that can be connected. More Details >>
- No:44984
- Release Date:2025/05/08 09:07
-
Regarding how to check the date of manufacture
You can check the LOT. on the front of the controller or the nameplate on the right side. Verifying on the front of the Controller Nameplate verification... More Details >>
- No:44968
- Release Date:2025/05/08 09:05
1-10 of Total 28