FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Automation Controllers MELSEC > MELSEC MX Controller MX-F Model
FAQ
Keyword Search
FAQ within [ MELSEC MX Controller MX-F Model ]
-
Regarding maintaining device back up
Battery: FX3U-32BL is not required for device back up.The battery is used to store clock data. More Details >>
- No:44976
- Release Date:2025/05/08 09:07
-
Regarding connectable Expansion Adapter
The MX-F Model can be connected to iQ-F series Expansion adapters. The following Expansion adapters can be connected. More Details >>
- No:44982
- Release Date:2025/05/08 09:06
-
Regarding the controller Line-up
The MX-F Model has the following features. More Details >>
- No:44964
- Release Date:2025/05/08 09:06
-
Regarding connectable I/O Modules
It is possible to connect the I/O Module of the MX-F Model to the extension cable type I/O Module of the iQ-F series. To connect an extension cable type I/O... More Details >>
- No:44965
- Release Date:2025/05/08 09:06
- Update:2025/11/05 08:03
-
Regarding the built-in motion function
The built-in motion function of the MX-F Model is programmed using motion control FB, wheareas the FX5-40/80SSC-G of the iQ-F series is programmed using buff... More Details >>
- No:44970
- Release Date:2025/06/18 14:38
-
Regarding number of internal Ethernet port connections
The Ethernet port (P2) has 32 connections. The breakdown is as follows: total of MELSOFT connections, SLMP, and socket communications ≦ 32 connections. Apa... More Details >>
- No:44974
- Release Date:2025/05/08 09:07
-
Regarding the available FB compilation methods
The MX-F Model only supports subroutine type FB. Please note that macro type FB is not supported. More Details >>
- No:44975
- Release Date:2025/05/08 09:07
-
The program cache memory (capacity) of the MX-F model is 12 MB. ※12 MB is equivalent to over 200K steps. More Details >>
- No:44990
- Release Date:2025/05/08 09:09
-
Regarding number of expansion adapter connections
The number of expansion adapters varies depending on the type of adapter, and up to six can be connected. ・Analog adapter: Up to 4 ・Communication adapter: ... More Details >>
- No:44966
- Release Date:2025/05/08 09:05
-
Regarding maximum number of connected stations for built-in CC-Link IE TSN
The maximum number of stations that can be connected in the network depends on the model name of the MX-F model. ・MXF100-16 N32/P32: Up to 46 stations ・MXF... More Details >>
- No:44973
- Release Date:2025/05/08 09:08
- Update:2025/10/31 15:18
1-10 of Total 28