FAQ


FAQAbout Products

- FAQ > Controllers > Programmable Automation Controllers MELSEC > MELSEC MX Controller MX-F Model
FAQ
Keyword Search
FAQ within [ MELSEC MX Controller MX-F Model ]
-
Regarding Always-On Special Relay Numbers
It is SM400. More Details >>
- No:44986
- Release Date:2025/05/08 09:08
-
Regarding the Program List Monitor
On the MX-F Model, the Performance Monitor function enables Program List Monitor. The operation cycle and load status of the core can be visualized. More Details >>
- No:44989
- Release Date:2025/05/08 09:08
-
The program cache memory (capacity) of the MX-F model is 12 MB. ※12 MB is equivalent to over 200K steps. More Details >>
- No:44990
- Release Date:2025/05/08 09:09
-
Regarding the built-in positioning function
The MX-F Model also supports the built-in positioning function. The number of control axes is now 4, and PULSE/SIGN and CW/CCW are supported. The maximum f... More Details >>
- No:44978
- Release Date:2025/05/08 09:08
-
Regarding iQ-F Series Project Conversion
It's possible. In GX Works3, select [Project] → [Change Module Type/Operation Mode], and select the Series: MX controller, Type/Model: MXF100, Number of Axes... More Details >>
- No:44987
- Release Date:2025/05/08 09:09
-
Regarding connectable I/O Modules
It is possible to connect the I/O Module of the MX-F Model to the extension cable type I/O Module of the iQ-F series. To connect an extension cable type I/O... More Details >>
- No:44965
- Release Date:2025/05/08 09:06
-
Regarding connectable Intelligent Function modules
The MX-F Model can be connected to the intelligent function modules of the iQ-F series. Connectable intelligent function modules are shown below. More Details >>
- No:44983
- Release Date:2025/05/08 09:06
-
Regarding the built-in motion function
The built-in motion function of the MX-F Model is programmed using motion control FB, wheareas the FX5-40/80SSC-G of the iQ-F series is programmed using buff... More Details >>
- No:44970
- Release Date:2025/06/18 14:38
-
Programming is possible with GX Works3. The supported version is 1.115V or later. More Details >>
- No:44962
- Release Date:2025/05/08 09:05
-
Regarding maximum number of input/output points
The maximum number of input/output points is 512. The number of remote I/O points is not limited, but can be used within the specification range of each int... More Details >>
- No:44971
- Release Date:2025/05/08 09:07
11-20 of Total 28