Energy Saving Supporting Devices
FAQ within [ Energy Saving Supporting Devices ]
-
As to Zero-Phase Current Transformer (ZCT) usable for the EcoMonitorPlus (Model: EMU4-LG1-MB).
Refer to the below table as to Zero-Phase Current Transformer usable for EcoMonitorPlus (Model: EMU4-LG1-MB). Note that the one made by another company is... More Details >>
- No:22129
- Release Date:2018/08/27 16:41
- Update:2018/08/31 14:17
- Category: Energy Measuring Units
-
Download of EcoWebServerIII graph data.
Currently displayed date graph is downloadable. Downloaded data is not changed only by changing the date. Change date, then press [Display] to update the g... More Details >>
- No:22116
- Release Date:2018/08/27 16:41
- Category: Energy Saving Data Collecting Servers
-
When displaying current value on EcoWebServerIII, the display goes blank.
Measuring error may have occurred. Please confirm in system log file on the web screen whether there are some errors occurred. If measuring error is detect... More Details >>
- No:22114
- Release Date:2018/08/27 16:41
- Category: Energy Saving Data Collecting Servers
-
The LED indication of the 7-segment rotates (EcoWebServerIII).
Where any CompactFlash card (hereinafter referred to as CF card) other than that supplied with this product is inserted, an indication of the 7-segment LED o... More Details >>
- No:22111
- Release Date:2018/08/27 16:41
- Update:2018/09/07 13:05
- Category: Energy Saving Data Collecting Servers
-
Display Unit (Model: EMU4-D65) manufactured in October 2016 or before is version A, S/W version: 1.05, which does not support either Pulse Input Unit (Model:... More Details >>
- No:38009
- Release Date:2020/11/12 13:03
- Category: Energy Measuring Units
-
Error No.001(EcoMonitorPlus, EcoMonitorLight)
Error "No. 001" means start failure of CC-Link communication unit. Please try either step. Solution: ・Press and hold the reset button of CC-Link communica... More Details >>
- No:24810
- Release Date:2019/03/27 14:44
- Category: Energy Measuring Units
-
Sample program for CC-LINK communication (EcoMonitorPlus/EcoMonitorLight)
Sample programs are described in Programming Manual. Please refer to suitable programming manual depending on CC-Link version which you use. ・Energy Measur... More Details >>
- No:24803
- Release Date:2019/03/27 12:12
- Category: Energy Measuring Units
-
Cause of "minus" indication for electric power value (EcoMonitorPlus/Light).
Following causes are assumed for the error. 1. Wrong orientation of the sensor? 2. 1-side and 3-side of the sensor are reversed? 3. Is connection betwe... More Details >>
- No:22143
- Release Date:2018/08/27 16:41
- Category: Energy Measuring Units
-
As to required number of Display Unit.
When reconnecting each unit, customer can use one unit for several purposes. Provided that if it is needed to display the measured value constantly, the numb... More Details >>
- No:22142
- Release Date:2018/08/27 16:41
- Category: Energy Measuring Units
-
As to logging after removing an SD memory card.
Since the EMU4-LM performs data logging, it is possible to log the data even in a state of removing the SD memory card. Provided that the period for data l... More Details >>
- No:22134
- Release Date:2018/08/27 16:41
- Category: Energy Measuring Units