Input derating is the percentage of simultaneous ON points, one of the specifications applied when input modules are used. When QX42 is used in a temperatur... More Details >>
- No:22692
- Release Date:2018/09/03 17:29
- Update:2018/10/03 16:23
- Category: MELSEC-Q Series
-
Update timing of LD75 current feed value and machine feed value
The values are updated at the timing described below. - Current feed value: 0.9 ms - Machine feed value: 0.9 ms More Details >>
- No:22748
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Compliance with SEMI-F47 for L series power supply module
Use the following power supply module with an input power of 200 VAC for compliance with SEMI-F47. - Power supply module: L61PWith an input power of 100 VAC,... More Details >>
- No:22768
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Versions of LCPU compatible with LJ71E71-100
The L series CPU serial numbers with upper 5 digits of "14112" or later indicate compatibility with LJ71E71-100. More Details >>
- No:22770
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
FNC connector pin layout in L series I/O module and Q series I/O module
Yes. They have the same pin layout. More Details >>
- No:22774
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
- Ambient temperature: 25+/-5degrees Celsius with tolerance of +/-0.1% - Ambient temperature: 0 to 55degrees Celsius with tolerance of +/-0.2% (Accuracy f... More Details >>
- No:22811
- Release Date:2018/09/03 17:30
- Update:2018/09/26 16:46
- Category: MELSEC-L Series
-
Maximum number of modules to be connected to L26CPU-(P)BT
Up to 40 modules. When the branch module and extension module are used, use L26CPU-(P)BT CPU modules whose first 5 digits of the serial number are "13072" or... More Details >>
- No:22813
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Statements of GX Works2 and the scan time
The input method for statements, either "PLC" or "Peripheral", makes a difference. - If "PLC" is set for statements, they are written into the program mem... More Details >>
- No:22856
- Release Date:2018/09/03 17:30
- Update:2018/09/22 14:18
- Category: Engineering Software
-
Adding statements to SFC programs
No statements can be added. Please add notes or comments instead. More Details >>
- No:22896
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Reception data read request signal of QJ71C24N not turn ON
The default receive complete code is CR+LF (0DH, 0AH). The default received data count is 511 words. Hence, at their defaults, Reception data read request si... More Details >>
- No:22984
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:22
- Category: Network related products