Controllers
FAQ within [ Controllers ]
-
Local device comments can be read if the comment file in which the local device comments are stored is written to the CPU module. More Details >>
- No:22869
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Program by program difference in comments on display
There are two types of device comments: "global device comment" and "local device comment". Device comments can be displayed in the ladder editor and Zoom... More Details >>
- No:22868
- Release Date:2018/09/03 17:30
- Update:2018/09/22 14:40
- Category: Engineering Software
-
Resolution provided for L60AD4
The maximum resolution for the user range setting does not change. More Details >>
- No:22827
- Release Date:2018/09/03 17:30
- Update:2018/09/22 15:24
- Category: MELSEC-L Series
-
Use of END cover with the branch module and extension module
Use an END cover applicable to the following. - The L6EC whose serial number (first six digits) is "*****2" or later- END cover with ERR terminal (optional i... More Details >>
- No:22815
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
The built-in I/O functions are standard functions of the L series CPU. Combining these functions flexibly achieves various controls with lower cost, eliminat... More Details >>
- No:22806
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
The number of LCPU extension blocks
(1) The number of modules to be connected- Main block: up to 10 modules- Extension block: up to 11 modules(2) The number of extension blocks- L02CPU, L02CPU-... More Details >>
- No:22750
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Update timing of LD75 current feed value and machine feed value
The values are updated at the timing described below. - Current feed value: 0.9 ms - Machine feed value: 0.9 ms More Details >>
- No:22748
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Turning OFF the power with the battery error occurring
The error history will be deleted. More Details >>
- No:22734
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
How to specify intelligent function module devices
For "U**", set the first two digits of the start I/O number of an intelligent function module in three-digit representation.Example) For X/Y1F0, set "U1F". More Details >>
- No:22704
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Update timing of QD75 current feed value and machine feed value
The values are updated at the timing described below.- Current feed value: 1.8 ms- Machine feed value: 56.8 ms More Details >>
- No:22689
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series