One license is required for each personal computer as a rule. More Details >>
- No:22561
- Release Date:2018/09/03 17:29
-
Is the version of MX Component compatible with Windows 7? Update the software to the version compatible with Windows 7 and then update the driver. For the ... More Details >>
- No:22569
- Release Date:2018/09/03 17:29
- Update:2018/09/20 16:50
-
It includes sample comments for special relay/special register and the intelligent function module. On the menu of GX Works2, select [Edit] -> [Import ... More Details >>
- No:22581
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:12
-
GX Works2's compatibility with the A series modules
GX Developer is automatically launched when A series is selected as a new project in GX Works2.For the A series modules, use GX Developer. More Details >>
- No:22594
- Release Date:2018/09/03 17:29
-
Socket communication with the built-in Ethernet port of a CPU module
The communication between programmable controllers can be established using the socket communication function instructions. More Details >>
- No:22596
- Release Date:2018/09/03 17:29
-
Q series device data held in the case of a power failure
The data in the devices assigned to Latch (1) or Latch (2) in the "Device Setting" window ([PLC Parameter] -> [Device Setting] window) is held when a pow... More Details >>
- No:22638
- Release Date:2018/09/03 17:29
- Update:2018/09/21 11:37
-
Print settings of the device list in GX Works2
When [Display Option] -> [Used devices] -> [Contact] and [Coil] are selected in the Device List window, devices used are not displayed. More Details >>
- No:22661
- Release Date:2018/09/03 17:29
- Update:2018/09/21 12:18
-
Intelligent function module settings in GX Works2
Modules do not need setting in GX Works2 if not selectable from "Module Selection" in the "New Module" window for intelligent function module settings. More Details >>
- No:22685
- Release Date:2018/09/03 17:29
-
Speeds of access to file registers
If file registers are registered in the standard RAM and "R" is specified by an instruction, the processing time is the same as is the case with the internal... More Details >>
- No:22688
- Release Date:2018/09/03 17:29
-
Update timing of QD75 current feed value and machine feed value
The values are updated at the timing described below.- Current feed value: 1.8 ms- Machine feed value: 56.8 ms More Details >>
- No:22689
- Release Date:2018/09/03 17:29