FAQ within [ MELSEC-Q Series ]
-
How to display local comments in GX Works2
In the "Reference/Reflection Target for Device Comment" window, switch the "Specify the Reference/Reflection" from "Global" to "Local". More Details >>
- No:22630
- Release Date:2018/09/03 17:29
-
How to copy comments from GX Developer to GX Works2
Launch GX Works2, select [Project] -> [Open Other Project], and read the data created with GX Developer. Copy the comment from the list of device comme... More Details >>
- No:22526
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:32
-
GX Developer's compatibility with 64-bit Windows 7
GX Developer Version 8.98C or later supports 64-bit Windows 7. To install GX Developer to a Windows 7-based personal computer, refer to the following techni... More Details >>
- No:22501
- Release Date:2018/09/03 17:28
- Update:2018/09/20 12:19
-
SD520 stores the current scan time in 1 ms units. More Details >>
- No:22556
- Release Date:2018/09/03 17:29
-
How to read the device memory in GX Works2
Select [Online] -> [Read from PLC] from the menu and check "Device Memory" in the file list in the window and then execute PLC read. More Details >>
- No:22621
- Release Date:2018/09/03 17:29
-
Inputting device comments in GX Works2
Select [Tool] -> [Options] -> [Program Editor] -> "Ladder/SFC"-> "Comment" and change "Reference/Reflection Target for Device Comment" from "Glob... More Details >>
- No:22559
- Release Date:2018/09/03 17:29
-
This occurs when the specified memory does not have consecutive free space in it. In this case, delete unnecessary files or arrange the PLC memory. Select ... More Details >>
- No:22604
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:03
-
Synchronizing the internal clock of a universal model QCPU
- When a built-in Ethernet port QCPU is used You can synchronize it with the server using the time setting function. -When a module other than built-in ... More Details >>
- No:22723
- Release Date:2018/09/03 17:29
- Update:2018/09/21 15:53
-
The error code "2400" is "FILE SET ERROR".It may be determined as the cause of the error that the file that has been specified by a parameter does not exist.... More Details >>
- No:22703
- Release Date:2018/09/03 17:29
-
Grounding FG and LG terminals of power supply module
Both of them need to be grounded. They can be shorted and grounded as one cable. More Details >>
- No:22527