Breaker trips/overcurrent error occurs.
Cause:Deterioration in the packing. Scaling on the packing. Using a highly permeable cutting oil. An environment that exceeds the IP functionality. Measures:... More Details >>
The hand does not move properly (air ...
Cause:An air leak/break in the piping. The solenoid bulb has failed. Wire breakage on the hand signal line. Hand signal line short circuitThe hand IF card ha... More Details >>
An unusual noise can be heard (from t...
Cause:Unusual noises can be caused by friction between movable parts, deformed parts, foreign matters getting inside, and defects in belt tension.An unusual ... More Details >>
The hand does not move properly (Elec...
Cause:Wire breakage on the hand signal line. The electronic hand controller(manufactured by TAIYO Ltd.) has failed. Faulty connection in the cables that run ... More Details >>
The T/B does not display anything.
Cause:The fuse (4A fuse) installed at the bottom of the 24 V power supply circuit in the controller may have blown out.For the fuse blowout, the emergency st... More Details >>
The leakage current breaker trips.
Cause:Incorrect breaker selection(current capacity/drive purpose, etc.). Leakage current due to electrically conductive foreign matters(oil/moisture) getting... More Details >>
The servo-on cannot be performed.
Cause:A servo OFF signal(SRVOFF)is being input from an external source. The operating right is not given.(IOENA parameters settings/exclusive input and outpu... More Details >>
Cause:Program error (arithmetic processing, etc.). Teaching operation error. Peripheral equipment is offset. There is a setting error in the origin position ... More Details >>
11-18 of Total 18