Brake is not working properly.
Cause:[Occurs only when operating manually]•T/B operation error.•The enabling device input is open.[Occurs when operating manually and automatically]•Faulty ... More Details >>
Cause:Deterioration in the reducer oil seal. Too much grease was applied. A grease other than the specified grease was applied. Excess grease left on the uni... More Details >>
The tip of the robot is vibrating.
Cause:The load conditions exceed the specified values(mass, inertia).The load condition settings are not suitable(HNDDAT and WRKDAT settings are not consiste... More Details >>
The communication fault occurs by the...
Cause:The Ethernet cable is not connected surely. There are the device etc. which cause the noise and the noise has applied to the Ethernet cable. Measures:C... More Details >>
The T/B does not display anything.
Cause:The fuse installed in the controller may have blown out. For the fuse blowout, there may be a ground fault or short circuit in the T/B cable. The T/B m... More Details >>
An unusual noise can be heard (from RC).
Cause:A noise is made as the internally mounted fan and its casing resonate. A noise is made by the fan catching internal wiring.Measures:Check the state of ... More Details >>
In automatic drive mode, the system d...
Cause: A stop signal(STOP/STOP2/SKIP) is being input from an external source. The operating right is not given.(IOENA parameters settings/exclusive input... More Details >>
Brake is not working properly.
Cause:[Occurs only when operating manually]•T/B operation error.[Occurs when operating manually and automatically]•Faulty connection of the cables that run b... More Details >>
Operation panel does not display anyt...
Cause:CPU has not started up properly.There is no power supply.An instantaneous power cut exceeding the specification level may have occurred.Measures:Check ... More Details >>
The operation panel does not light up...
Cause: AC line inside the controller may have detected the abnormalities. Measures: Check that the primary side’s power supply voltage is being su... More Details >>