Start main contents

  • Font Size
  • S
  • M
  • L

FAQ within [ Ceiling mounted, holizontal type robot ]

11-18 of Total 18

prev 2 / 2page next
  • Brake is not working properly.

    Cause:[Occurs only when operating manually]•T/B operation error.[Occurs when operating manually and automatically]•Faulty connection of the cables that run b... More Details >>

    • No:23178
    • Release Date:2018/09/07 16:09
  • In automatic drive mode, the system d...

    Cause: A stop signal(STOP/STOP2/SKIP) is being input from an external source. The operating right is not given.(IOENA parameters settings/exclusive input... More Details >>

    • No:23171
    • Release Date:2018/09/07 16:09
    • Update:2018/10/03 14:48
  • An unusual noise can be heard (from RC).

    Cause:A noise is made as the internally mounted fan and its casing resonate. A noise is made by the fan catching internal wiring.Measures:Check the state of ... More Details >>

    • No:23168
    • Release Date:2018/09/07 16:09
  • The T/B does not display anything.

    Cause:The fuse installed in the controller may have blown out. For the fuse blowout, there may be a ground fault or short circuit in the T/B cable. The T/B m... More Details >>

    • No:23180
    • Release Date:2018/09/07 16:09
  • The communication fault occurs by the...

    Cause:The Ethernet cable is not connected surely. There are the device etc. which cause the noise and the noise has applied to the Ethernet cable. Measures:C... More Details >>

    • No:23179
    • Release Date:2018/09/07 16:09
  • The tip of the robot is vibrating.

    Cause:The load conditions exceed the specified values(mass, inertia).The load condition settings are not suitable(HNDDAT and WRKDAT settings are not consiste... More Details >>

    • No:23169
    • Release Date:2018/09/07 16:09
  • Oil is leaking.

    Cause:Deterioration in the reducer oil seal. Too much grease was applied. A grease other than the specified grease was applied. Excess grease left on the uni... More Details >>

    • No:23174
    • Release Date:2018/09/07 16:09
  • Brake is not working properly.

    Cause:[Occurs only when operating manually]•T/B operation error.•The enabling device input is open.[Occurs when operating manually and automatically]•Faulty ... More Details >>

    • No:23183
    • Release Date:2018/09/07 16:09

11-18 of Total 18