FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-R Series
FAQ
Keyword Search
FAQ within [ MELSEC iQ-R Series ]
-
Using Q series terminal blocks and connectors with MELSEC iQ-R series modules
You can use a Q series 18-point screw terminal block with a MELSEC iQ-R series terminal block type I/O module or analog module. For a 40-pin connector type ... More Details >>
- No:22474
- Release Date:2018/09/03 17:28
- Update:2018/09/19 14:37
-
IP filter function of MELSEC iQ-R series CPU modules
You can set IP addresses accessible to the CPU module and prevent unauthorized access to the CPU module. <Setting the IP filter function> [Navigati... More Details >>
- No:22479
- Release Date:2018/09/03 17:28
- Update:2018/09/19 15:01
-
I cannot place a main base unit in a module configuration diagram with GX Works3.
You may have already placed a main base unit in the module configuration diagram. Scroll up or down in the module configuration diagram and check if a main ... More Details >>
- No:22487
- Release Date:2018/09/03 17:28
- Update:2018/09/20 09:37
-
Processing time of when multiple programs are executed with a MELSEC iQ-R series CPU module
When multiple programs are executed, the processing time (program switching time) becomes "Number of program files × 0.9 [us]". More Details >>
- No:22491
- Release Date:2018/09/03 17:28
- Update:2018/09/20 09:49
-
You can synchronize the fixed scan communication cycle of the multiple CPU system function with the inter-module synchronization cycle of the inter-module s... More Details >>
- No:22494
- Release Date:2018/09/03 17:28
- Update:2018/09/20 11:12
-
Database function of the MELSEC iQ-R series
You can manage tabular data including product information and production information as a database in a programmable controller. By accessing the database w... More Details >>
- No:22477
- Release Date:2018/09/03 17:28
- Update:2018/09/19 14:53
-
The number of modules that can be synchronized is as follows. - In single CPU system configuration: 64 modules - In multiple CPU system configuration: 57 t... More Details >>
- No:22496
- Release Date:2018/09/03 17:28
- Update:2018/09/21 17:15
-
How to display the parameter setting window for a programmable controller with GX Works3
You can display the setting window from a module configuration diagram or system parameters. <Displaying the setting window from a module configuration... More Details >>
- No:22498
- Release Date:2018/09/03 17:28
- Update:2018/09/20 12:10
-
Although it depends on interrupt factors, the overhead time before startup becomes 10.8 to 23.8 [us] and the time after startup becomes 6.5 to 17.4 [us]. More Details >>
- No:22499
- Release Date:2018/09/03 17:28
- Update:2018/09/20 12:14
-
Digit specification for bit devices in ST language with GX Works3
For a label where digits are to be specified, set a bit type array as its data type. The following shows an example of when a global label is used. - Globa... More Details >>
- No:22455
- Release Date:2018/09/03 17:28
- Update:2018/09/18 15:01