Relay life of the MELSEC iQ-R series relay output module (RY10R2)
The mechanical life of the module is 20 million times or longer. The relay life (contact switching life) of the module varies depending on the usage environ... More Details >>
- No:22457
- Release Date:2018/09/03 17:28
- Update:2018/09/21 16:12
-
Using a commercially-available SD memory card for a MELSEC iQ-R series CPU module
For the commercially-available SD memory cards that can be used for MELSEC iQ-R series CPU modules, refer to the following technical bulletin. - TECHNICAL ... More Details >>
- No:22461
- Release Date:2018/09/03 17:28
- Update:2018/09/18 15:46
-
I/O numbers of a MELSEC iQ-R series I/O combined module (RH42C4NT2P)
An input and output use a single I/O number. (This is the same as QH42P.) When you replace a module that uses serial I/O numbers (e.g. QX41Y41P) with this m... More Details >>
- No:22471
- Release Date:2018/09/03 17:28
- Update:2018/09/19 13:57
-
Using Q series terminal blocks and connectors with MELSEC iQ-R series modules
You can use a Q series 18-point screw terminal block with a MELSEC iQ-R series terminal block type I/O module or analog module. For a 40-pin connector type ... More Details >>
- No:22474
- Release Date:2018/09/03 17:28
- Update:2018/09/19 14:37
-
Database function of the MELSEC iQ-R series
You can manage tabular data including product information and production information as a database in a programmable controller. By accessing the database w... More Details >>
- No:22477
- Release Date:2018/09/03 17:28
- Update:2018/09/19 14:53
-
I cannot place a main base unit in a module configuration diagram with GX Works3.
You may have already placed a main base unit in the module configuration diagram. Scroll up or down in the module configuration diagram and check if a main ... More Details >>
- No:22487
- Release Date:2018/09/03 17:28
- Update:2018/09/20 09:37
-
Built-in Ethernet function setting window of MELSEC iQ-R series CPU modules
"Module Parameter" of the CPU module is the setting window. <Setting a built-in Ethernet port> [Navigation Window]-> [Parameter]-> [CPU Modul... More Details >>
- No:22488
- Release Date:2018/09/03 17:28
- Update:2018/09/20 09:40
-
In the communication of the CC-Link IE Field Network synchronous communication function, you can synchronize the timing to send/receive data with the inter-... More Details >>
- No:22493
- Release Date:2018/09/03 17:28
- Update:2018/09/20 11:10
-
You can synchronize the fixed scan communication cycle of the multiple CPU system function with the inter-module synchronization cycle of the inter-module s... More Details >>
- No:22494
- Release Date:2018/09/03 17:28
- Update:2018/09/20 11:12
-
The number of modules that can be synchronized is as follows. - In single CPU system configuration: 64 modules - In multiple CPU system configuration: 57 t... More Details >>
- No:22496