You can synchronize the fixed scan communication cycle of the multiple CPU system function with the inter-module synchronization cycle of the inter-module s... More Details >>
- No:22494
- Release Date:2018/09/03 17:28
- Update:2018/09/20 11:12
-
Interrupt program priority setting of MELSEC iQ-R series
You can set interrupt priorities 5 to 7 for interrupt pointers (I0 to I15, I50 to I1023) from the module. You cannot change the priorities of interrupt poin... More Details >>
- No:22482
- Release Date:2018/09/03 17:28
- Update:2018/09/19 16:05
-
Setting the MELSEC iQ-R series inter-module synchronization function
Set modules in a module configuration diagram with GX Works3 and configure the inter-module synchronization setting. [Navigation Window]-> [Parameter]-... More Details >>
- No:22492
- Release Date:2018/09/03 17:28
- Update:2018/09/20 10:01
-
I cannot place a main base unit in a module configuration diagram with GX Works3.
You may have already placed a main base unit in the module configuration diagram. Scroll up or down in the module configuration diagram and check if a main ... More Details >>
- No:22487
- Release Date:2018/09/03 17:28
- Update:2018/09/20 09:37
-
How to display the multiple CPU function setting window of MELSEC iQ-R series CPU modules
You can display the setting window in the multiple CPU setting of system parameters. <Multiple CPU setting> [Navigation Window]-> [Parameter]-&g... More Details >>
- No:22484
- Release Date:2018/09/03 17:28
- Update:2018/09/19 16:13
-
How to change the specified connection destination of GX Works3
You can change the destination in [Online]-> [Specify Connection Destination]. Change the destination depending on the communication path to be used. Yo... More Details >>
- No:22472
- Release Date:2018/09/03 17:28
- Update:2018/09/19 14:31
-
Duplicated coil errors that can be checked with GX Works3
When an SET instruction and RST instruction use a single device, no duplicated coil error is detected. More Details >>
- No:22456
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:33
-
In the communication of the CC-Link IE Field Network synchronous communication function, you can synchronize the timing to send/receive data with the inter-... More Details >>
- No:22493
- Release Date:2018/09/03 17:28
- Update:2018/09/20 11:10
-
Interrupt period setting of fixed scan interrupts of MELSEC iQ-R series
You can configure the setting in "Interrupt Setting from Internal Timer" of the CPU parameter. <Interrupt period setting> [Navigation Window]-> ... More Details >>
- No:22490
- Release Date:2018/09/03 17:28
- Update:2018/09/20 09:46
-
Operations that can be performed with the MELSEC iQ-R series inter-module synchronization function
The inter-module synchronization function synchronizes the input or output timing of multiple I/O modules or intelligent function modules. The inter-... More Details >>