FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-R Series
FAQ
Keyword Search
FAQ within [ MELSEC iQ-R Series ]
-
IP filter function of MELSEC iQ-R series CPU modules
You can set IP addresses accessible to the CPU module and prevent unauthorized access to the CPU module. <Setting the IP filter function> [Navigati... More Details >>
- No:22479
- Release Date:2018/09/03 17:28
- Update:2018/09/19 15:01
-
Duplicated coil errors that can be checked with GX Works3
When an SET instruction and RST instruction use a single device, no duplicated coil error is detected. More Details >>
- No:22456
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:33
-
Database function of the MELSEC iQ-R series
You can manage tabular data including product information and production information as a database in a programmable controller. By accessing the database w... More Details >>
- No:22477
- Release Date:2018/09/03 17:28
- Update:2018/09/19 14:53
-
Built-in Ethernet function setting window of MELSEC iQ-R series CPU modules
"Module Parameter" of the CPU module is the setting window. <Setting a built-in Ethernet port> [Navigation Window]-> [Parameter]-> [CPU Modul... More Details >>
- No:22488
- Release Date:2018/09/03 17:28
- Update:2018/09/20 09:40
-
Interrupt period setting of fixed scan interrupts of MELSEC iQ-R series
You can configure the setting in "Interrupt Setting from Internal Timer" of the CPU parameter. <Interrupt period setting> [Navigation Window]-> ... More Details >>
- No:22490
- Release Date:2018/09/03 17:28
- Update:2018/09/20 09:46
-
Digit specification for bit devices in ST language with GX Works3
For a label where digits are to be specified, set a bit type array as its data type. The following shows an example of when a global label is used. - Globa... More Details >>
- No:22455
- Release Date:2018/09/03 17:28
- Update:2018/09/18 15:01
-
You can synchronize the fixed scan communication cycle of the multiple CPU system function with the inter-module synchronization cycle of the inter-module s... More Details >>
- No:22494
- Release Date:2018/09/03 17:28
- Update:2018/09/20 11:12
-
Mounting Q series modules on a MELSEC iQ-R series base unit
You cannot mount Q series modules on a MELSEC iQ-R series base unit. Use an RQ extension base unit (RQ65B, RQ68B, or RQ612B). You cannot mount some modules... More Details >>
- No:22466
- Release Date:2018/09/03 17:28
- Update:2018/09/19 11:58
-
Using a commercially-available SD memory card for a MELSEC iQ-R series CPU module
For the commercially-available SD memory cards that can be used for MELSEC iQ-R series CPU modules, refer to the following technical bulletin. - TECHNICAL ... More Details >>
- No:22461
- Release Date:2018/09/03 17:28
- Update:2018/09/18 15:46
-
When the block number of the file register (R) is saved and stored, the overhead time becomes 35.9 [us]. When the number of the file register is not saved o... More Details >>
- No:22465
- Release Date:2018/09/03 17:28
- Update:2018/09/19 11:57
31-40 of Total 45