FAQ


FAQAbout Products

- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-R Series
FAQ
Keyword Search
FAQ within [ MELSEC iQ-R Series ]
-
Models of batteries that can be used with MELSEC iQ-R series CPU modules
You can use "Q6BAT" and "Q7BAT". You cannot use "Q8BAT". More Details >>
- No:22469
- Release Date:2018/09/03 17:28
-
Although it depends on interrupt factors, the overhead time before startup becomes 10.8 to 23.8 [us] and the time after startup becomes 6.5 to 17.4 [us]. More Details >>
- No:22499
- Release Date:2018/09/03 17:28
- Update:2018/09/20 12:14
-
How to prevent unauthorized access to MELSEC iQ-R series CPU modules via a network
The MELSEC iQ-R series CPU module has "IP filter function" and "remote password function" as security functions. With the "IP filter function", you can set ... More Details >>
- No:22478
- Release Date:2018/09/03 17:28
- Update:2018/09/19 14:58
-
Database function of the MELSEC iQ-R series
You can manage tabular data including product information and production information as a database in a programmable controller. By accessing the database w... More Details >>
- No:22477
- Release Date:2018/09/03 17:28
- Update:2018/09/19 14:53
-
Digit specification for bit devices in ST language with GX Works3
For a label where digits are to be specified, set a bit type array as its data type. The following shows an example of when a global label is used. - Globa... More Details >>
- No:22455
- Release Date:2018/09/03 17:28
- Update:2018/09/18 15:01
-
Accessories of the MELSEC iQ-R series 40-pin connector type module
No connector is provided with the module. Separately prepare any of the following connectors. A6CON1: Soldering type 32-point connector (40-pin connector) A6... More Details >>
- No:22467
- Release Date:2018/09/03 17:28
-
IP filter function of MELSEC iQ-R series CPU modules
You can set IP addresses accessible to the CPU module and prevent unauthorized access to the CPU module. <Setting the IP filter function> [Navigati... More Details >>
- No:22479
- Release Date:2018/09/03 17:28
- Update:2018/09/19 15:01
-
You can synchronize the fixed scan communication cycle of the multiple CPU system function with the inter-module synchronization cycle of the inter-module s... More Details >>
- No:22494
- Release Date:2018/09/03 17:28
- Update:2018/09/20 11:12
-
I/O numbers of a MELSEC iQ-R series I/O combined module (RH42C4NT2P)
An input and output use a single I/O number. (This is the same as QH42P.) When you replace a module that uses serial I/O numbers (e.g. QX41Y41P) with this m... More Details >>
- No:22471
- Release Date:2018/09/03 17:28
- Update:2018/09/19 13:57
-
I cannot place a main base unit in a module configuration diagram with GX Works3.
You may have already placed a main base unit in the module configuration diagram. Scroll up or down in the module configuration diagram and check if a main ... More Details >>
- No:22487
- Release Date:2018/09/03 17:28
- Update:2018/09/20 09:37
1-10 of Total 45