Regarding MODBUS Device Allocation Settings
No need. The MODBUS device allocation settings are used when the MODBUS slave function is used. More Details >>
- No:40026
- Release Date:2023/08/24 14:37
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding Instruction description help in GX Works3
You can open the descriptions for each instruction by moving the cursor to the target instruction and pressing F1. You can also hover the cursor over it and ... More Details >>
- No:39366
- Release Date:2023/02/15 13:06
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding the difference of current address (user unit, pulse unit)
The difference between the current address (user unit) and the current address (pulse unit) is as follows: The current address (user unit) becomes the unit ... More Details >>
- No:39357
- Release Date:2023/02/15 13:05
- Category: MELSEC iQ-F Series , CPU Module , Motion/Positioning
-
Regarding changing the current address (user unit, pulse unit)
It can be changed. It is now possible to write to the address (user unit, pulse unit) by the DHCMOV command. However, writing is disabled during positioning... More Details >>
- No:39356
- Release Date:2023/02/15 13:03
- Category: MELSEC iQ-F Series , CPU Module , Motion/Positioning
-
Regarding handling multiple executions of ADPRW Instructions
When multiple ADPRW instructions are simultaneously executed, communication by the ADPRW command that was executed earlier is completed and communication by ... More Details >>
- No:39354
- Release Date:2023/02/15 10:17
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding reading Sample Comments for Expansion Adapters
You cannot. The expansion adapters does not support reading sample comments. More Details >>
- No:39352
- Release Date:2023/02/15 10:16
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding the differences between Latches (1) and (2)
Whether or not the latch range is set by default and the range to "clear values" from CPU memory operations are different. You can clear with two options: c... More Details >>
- No:39351
- Release Date:2023/02/15 13:08
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding how to back up FX5-4LC
Some buffer memory values are cleared when the power is turned off. Turn on the backup command before turning the power OFF. By turning the buffer memory ... More Details >>
- No:39347
- Release Date:2023/01/16 10:07
- Category: MELSEC iQ-F Series , Analog
-
It cannot. Because there will be two CC-link IE field network Basic master stations in a network. More Details >>
- No:39346
- Release Date:2023/02/15 10:05
- Update:2024/04/25 10:10
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the possibility of adding an additional module to the FX5S CPU module
You cannot. The FX5S CPU module does not support the connection of an additional module (I/O module, Intelligent function module, FX5 safety extension modul... More Details >>
- No:39339
- Release Date:2023/02/14 17:28
- Category: MELSEC iQ-F Series , CPU Module