Regarding the simultaneous use of Simple CPU Communication and FX5-CCLGN-MS MELSOFT Connection
Can be used simultaneously. More Details >>
- No:39285
- Release Date:2023/01/12 16:50
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the switching Hubs that can be used for CC-Link IE TSN
The CC-Link IE TSN has a CC-Link IE TSN Class B/A, and the available switching HUBs are also specified by supported standards, synchronization accuracy, etc.... More Details >>
- No:39284
- Release Date:2023/01/12 16:50
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the connection between FX5-CCLGN-MS and inverter
FX5-CCLGN-MS supports 1 Gbps communication speed with firmware version: 1.010, and 1 Gbps and 100 Mbps communication speed for version 1.010. If the communi... More Details >>
- No:39281
- Release Date:2023/01/12 16:48
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the change of settings for reserved station (master station) of FX5-CCLGN-MS
FX5-CCLGN-MS allows the master station to change the reserved station setting with parameters, but the setting can not be changed by program. Note that link... More Details >>
- No:39275
- Release Date:2023/01/12 16:46
- Category: MELSEC iQ-F Series , Network/Communication
-
Input filter adjustment when a high-speed counter or the interrupt function is used
When a coil of the high-speed counter or an interrupt pointer is programmed, the programmable controller system adjusts the filter constant of the correspond... More Details >>
- No:24867
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series , High-Speed Counter
-
Regarding expansion of communication ports
It is possible to use the MODBUS serial communication with multiple channels. However, only 1 channel can be set as the master. The MODBUS serial communica... More Details >>
- No:22323
- Release Date:2018/08/30 13:55
- Update:2023/06/26 09:04
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the connection configuration of FX5-CCL-MS
Connection is not allowed. For FX5-CCL-MS, only remote I/O stations, remote device stations andintelligent device stationscan be connected. More Details >>
- No:22316
- Release Date:2018/08/30 13:55
- Update:2023/07/03 17:19
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the maximum number of channels of high-speed counters
The FX5 CPU module's built-in high-speed counter can control up to 8CH. Up to 16CH can be controlled by adding 4 modules of FX5-16ET/E□-H (high-speed pulse ... More Details >>
- No:22311
- Release Date:2018/08/30 13:55
- Update:2023/02/13 15:34
- Category: MELSEC iQ-F Series , CPU Module , High-Speed Counter
-
Regarding the number of available channels of the built-in high speeed counters.
The high-speed counter supports 1-phase 1-input, 1-phase 2-input, 2-phase 2-input. The built-in counter in the CPU module can input up to 8ch. However,... More Details >>
- No:22310
- Release Date:2018/08/30 13:55
- Update:2023/02/13 11:42
- Category: MELSEC iQ-F Series , CPU Module , High-Speed Counter
-
As the parameter settings of the FX3 intelligent function modules are not supported by GX Works3, they cannot be selected from the element selection window.... More Details >>