Regarding the change of settings for reserved station (master station) of FX5-CCLGN-MS
FX5-CCLGN-MS allows the master station to change the reserved station setting with parameters, but the setting can not be changed by program. Note that link... More Details >>
- No:39275
- Release Date:2023/01/12 16:46
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the connection between FX5-CCLGN-MS and NZ2GN2S-60AD4
Available. More Details >>
- No:39279
- Release Date:2023/01/12 16:47
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the connection between FX5-CCLGN-MS and inverter
FX5-CCLGN-MS supports 1 Gbps communication speed with firmware version: 1.010, and 1 Gbps and 100 Mbps communication speed for version 1.010. If the communi... More Details >>
- No:39281
- Release Date:2023/01/12 16:48
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding CC-Link IE TSN System Configuration with Mixed CC-Link IE TSN Class B/A Equipment
The boundary between the area of CC-Link IE TSN Class B equipment and the area of CC-Link IE TSN Class A equipment can use a general-purpose switching HUB an... More Details >>
- No:39283
- Release Date:2023/01/12 16:49
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the simultaneous use of Simple CPU Communication and FX5-CCLGN-MS MELSOFT Connection
Can be used simultaneously. More Details >>
- No:39285
- Release Date:2023/01/12 16:50
- Category: MELSEC iQ-F Series , Network/Communication
-
The FX5 CPU module does not support CAN communication. More Details >>
- No:39286
- Release Date:2023/02/13 15:36
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the number of terminating resistors of FX5-CCL-MS
Two terminating resistors are included. More Details >>
- No:39290
- Release Date:2023/01/12 16:52
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding clearing error with SM50
It is cleared by eliminating the cause of the error during detection and turning on SM50. For the error codes that can be cleared on the SM50, refer to the ... More Details >>
- No:39292
- Release Date:2023/02/13 15:37
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding "_ U" in Application Instruction
It means an instruction that handles BIN 16 bit and BIN 32 bit unsigned data. Example:ADD _ U More Details >>
- No:39295
- Release Date:2023/02/13 16:37
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding Extended File Register (ER) file names
File names can not be changed. It is fixed to EXFILER.ERD. More Details >>
- No:39296
- Release Date:2023/02/13 16:39
- Category: MELSEC iQ-F Series , CPU Module