FAQ within [ MELSEC-Q Series ]
-
There are no settings for deleting the network number and PC number. More Details >>
- No:22708
- Release Date:2018/09/03 17:29
-
Change timing of the status of A/D conversion module's I/O signals
(1)If the A/D conversion enable signal is kept ON, conversion processing is kept performed. Once conversion processing is successfully performed, A/D conve... More Details >>
- No:22710
- Release Date:2018/09/03 17:29
- Update:2018/09/21 15:12
-
Settings of the built-in Ethernet port of the universal model QCPU
Make settings of the built-in Ethernet port in the [Built-in Ethernet Port Setting] tab of the PLC parameter in GX Works2 or GX Developer. More Details >>
- No:22618
- Release Date:2018/09/03 17:29
- Update:2018/09/21 10:06
-
Parameter settings required to use the MODBUS(R) interface module as a slave station
If preset initial values are used, parameters do not need setting.If changing the basic parameter or MODBUS(R) device assignment parameter, use a sequence pr... More Details >>
- No:22680
- Release Date:2018/09/03 17:29
-
FL-net interface module setting
The auto refresh setting is not required. However, making the setting can reduce communication programs. More Details >>
- No:22588
- Release Date:2018/09/03 17:29
-
Life expectancy of the CompactFlash card used in the high speed data logger module
The life expectancy is determined by the following calculation.Life expectancy (year) = Total writable size (GB) / 1 year write size (GB/year)For more detail... More Details >>
- No:22592
- Release Date:2018/09/03 17:29
-
Intelligent function module settings in GX Works2
Intelligent function module settings can be made using GX Works2 alone.GX Works2 provides functions equivalent to various GX Configurator series functions.Fo... More Details >>
- No:22593
- Release Date:2018/09/03 17:29
-
Communication between Ethernet and FL-net
The communication between the Ethernet interface module and FL-net (OPCN-2) interface module cannot be established. More Details >>
- No:22683
- Release Date:2018/09/03 17:29
-
Memory allocation for online change in GX Developer
Select [Online] -> [Write to PLC] on the menu of GX Developer, open the [File selection] tab, and press "Param + Prog" button. Then open the [Program] ta... More Details >>
- No:22547
- Release Date:2018/09/03 17:28
- Update:2018/09/20 15:09
-
Compatibility with 64-bit Windows 7
GX Works2 Version 1.62Q or later supports Windows 7. More Details >>
- No:22554
- Release Date:2018/09/03 17:28