FAQ


FAQAbout Products

- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC-Q Series
FAQ
Keyword Search
FAQ within [ MELSEC-Q Series ]
-
Battery life in the universal model QCPU
It depends on the model of the CPU module, the amount of battery consumption, and the power-on time ratio. Example) For Q06UDHCPU with power-on time ratio... More Details >>
- No:22633
- Release Date:2018/09/03 17:29
- Update:2018/09/21 11:28
-
Whether or not totem pole output type encoders are connected
Totem pole output encoders cannot be connected to QD62.The following types of encoders can be connected.- Open collector output type encoders- CMOS level vol... More Details >>
- No:22641
- Release Date:2018/09/03 17:29
-
Difference between GX Works2 and GX Works
GX Works2 is programmable controller engineering software integrating programming and simulation of programmable controller and setting monitor tool functio... More Details >>
- No:22505
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:16
-
PLC write not possible due to memory overload
If comments cannot be stored in the program memory, write them in the standard ROM or a memory card. Calculate the memory capacity in GX Works2 or GX Develo... More Details >>
- No:22595
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:49
-
COMMENT to disappear after a PLC type change
Copy the COMMENT into the MAIN of comments by program before changing the PLC type.The basic model QCPU cannot deal with common comments. More Details >>
- No:22625
- Release Date:2018/09/03 17:29
-
Setting of "Target MODBUS(R) device head number"
Set "(Last five digits of actual device number) - 1" for the Target MODBUS(R) device head number.Example) For the holding register 400018, set "17". More Details >>
- No:22682
- Release Date:2018/09/03 17:29
-
How to check automatically assigned devices in GX Works2
Click the local label to be checked and select "Cross Reference" from the right-click menu to check the devices. More Details >>
- No:22700
- Release Date:2018/09/03 17:29
-
How to check errors with error codes of QD75
Errors can be checked with the following error detection signals and buffer memory areas corresponding to each axis.- Axis 1 Error detection X8 Buffer memor... More Details >>
- No:22667
- Release Date:2018/09/03 17:29
-
Intelligent function module settings in GX Works2
Modules do not need setting in GX Works2 if not selectable from "Module Selection" in the "New Module" window for intelligent function module settings. More Details >>
- No:22685
- Release Date:2018/09/03 17:29
-
CSV format import/export capability of GX Works2
From version 1.64S, GX Works2 can import/export device comments in CSV format but does not support the function for parameters equivalent to that of GX Conve... More Details >>
- No:22643
- Release Date:2018/09/03 17:29
1-10 of Total 213