FAQ within [ MELSEC-Q Series ]
-
Ladder programs for GX Configurator-FL
When GX Configurator-FL is used, programs for initial settings and cyclic data reading and writing are not needed. More Details >>
- No:22658
- Release Date:2018/09/03 17:29
-
How to set a value in SM414(2n second clock)
Set a value in the special register SD414.Use a MOV instruction to set the value in SD414. More Details >>
- No:22639
- Release Date:2018/09/03 17:29
-
CPU modules that support the File Register Extended Setting
The universal model QCPU modules other than Q00UJCPU support the File Register Extended Setting. More Details >>
- No:22627
- Release Date:2018/09/03 17:29
-
GX Works2's compatibility with Monitor (write mode)
From version 1.62Q, GX Works2 supports Monitor (write mode). Pressing Shift+F4 allows an online change. More Details >>
- No:22612
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:18
-
How to write to file registers in Q series
Specify the file in the Write to PLC window and execute writing. More Details >>
- No:22585
- Release Date:2018/09/03 17:29
-
Necessities for the execution environment of MX Component
Both the developed software and MX Component must be installed. More Details >>
- No:22557
- Release Date:2018/09/03 17:29
- Update:2018/09/20 15:53
-
Heat generation of Q61P power supply module
Since the conversion efficiency of the power supply module is approximately 70%, and 30% of the output power is dissipated as heat, the power consumption is ... More Details >>
- No:22529
- Release Date:2018/09/03 17:28
-
How to use file registers R in the Q series
File registers R can be used for data whose size is exceeding 32k points with RSET instruction, which is a block switching instruction. Use file registers... More Details >>
- No:22525
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:29
-
Update timing of QD75 current feed value and machine feed value
The values are updated at the timing described below.- Current feed value: 1.8 ms- Machine feed value: 56.8 ms More Details >>
- No:22689
- Release Date:2018/09/03 17:29
-
How to read comments in the standard ROM with GX Works2
Select [Target Memory] -> [Standard ROM] in the Read from PLC window. More Details >>
- No:22673
- Release Date:2018/09/03 17:29
- Update:2018/09/21 14:05