- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC-Q Series
FAQ
Keyword Search
FAQ within [ MELSEC-Q Series ]
-
Software required for MX Sheet
MX Component and EXCEL are required. More Details >>
- No:22646
- Release Date:2018/09/03 17:29
-
QnA-compatible 3E frame command (0406) for the built-in Ethernet port QCPU
The built-in Ethernet port QCPU is not compatible with a multiple-block batch read command (0406) of the MC protocol. Executable commands are the following.... More Details >>
- No:22608
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:09
-
You can use the output change upper limit value and the MV upper/lower limit limiter, the functions common to each PID control tag. Set the following parame... More Details >>
- No:22724
- Release Date:2018/09/03 17:29
- Update:2018/09/26 16:40
-
Update timing of QD75 current feed value and machine feed value
The values are updated at the timing described below.- Current feed value: 1.8 ms- Machine feed value: 56.8 ms More Details >>
- No:22689
- Release Date:2018/09/03 17:29
-
The numbers of POUs and steps of "Allocate Memory for 'Online Change'" in GX Works2
The maximum number of steps that an online change can process at a time is 512. More Details >>
- No:22672
- Release Date:2018/09/03 17:29
-
Print settings of the device list in GX Works2
When [Display Option] -> [Used devices] -> [Contact] and [Coil] are selected in the Device List window, devices used are not displayed. More Details >>
- No:22661
- Release Date:2018/09/03 17:29
- Update:2018/09/21 12:18
-
Difference between QH42P and QX41Y41P
The difference is I/O numbers used for input and output (XY). QH42P uses the same I/O numbers both for input and output. QX41Y41P uses sequential I/O numbers... More Details >>
- No:22539
- Release Date:2018/09/03 17:28
-
Behavior of special relay in simulation
The constant scan initial value in the simulation function is 100ms. Thus, the value of SM410(0.1sec. clock) is OFF in each scan. To turn ON/OFF SM410, set ... More Details >>
- No:22521
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:23
-
It means that in an ambient temperature of 25 degrees Celsius, an error per day falls within the range of "delay of 2.57s" to "advance of 5.27s". "TYP.+2.22... More Details >>
- No:22651
- Release Date:2018/09/03 17:29
- Update:2018/09/26 16:53
-
Capacity setting of file registers
Set 96K points. (1K point = 1024 points) More Details >>
- No:22610
- Release Date:2018/09/03 17:29