Update timing of QD75 current feed value and machine feed value
The values are updated at the timing described below.- Current feed value: 1.8 ms- Machine feed value: 56.8 ms More Details >>
- No:22689
- Release Date:2018/09/03 17:29
-
Making transparent connections using GX Developer
Set as follows in the Transfer Setup window. - Select "USB" for "PC side I/F". - Select "CPU Module" for "PLC side I/F" and check "via GOT (direct couple... More Details >>
- No:22640
- Release Date:2018/09/03 17:29
- Update:2018/09/21 11:39
-
Turning OFF the power with the battery error occurring
It deletes the error history. More Details >>
- No:22545
- Release Date:2018/09/03 17:28
-
Those displayed under COMMENT are common comments, and others are program comments.When there are multiple programs in a project, a common comment applies to... More Details >>
- No:22540
- Release Date:2018/09/03 17:28
-
Simulation function not started
The simulation function utilizes the standard TCP/IP communication provided by Microsoft Corporation. A communication capability of software of another make... More Details >>
- No:22631
- Release Date:2018/09/03 17:29
- Update:2018/09/21 10:45
-
Difference between Q24DHCCPU-V and Q12DCCPU-V
Hardware specifications are different. For hardware specifications, refer to the following manuals. - MELSEC-Q C Controller Module User's Manual - C Contro... More Details >>
- No:22629
- Release Date:2018/09/03 17:29
- Update:2018/09/21 10:41
-
Set as follows in the Transfer Setup window. - Select "USB" for "PC side I/F". - Select "GOT" for "PLC side I/F" and select "via GOT (direct coupled) tra... More Details >>
- No:22598
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:55
-
Reading and writing bits/words using the FL-net (OPCN-2) interface module
The parameters and auto refresh settings for the FL-net (OPCN-2) interface module cannot be made using the Network Parameter items in GX Developer.Set those ... More Details >>
- No:22597
- Release Date:2018/09/03 17:29
-
Cause of file register reset by latch clear operation in universal model QCPU
If Latch (1) is set in the device setting of PLC parameter, the contents of file registers are cleared by latch clear operation. Set Latch (2) to maintain t... More Details >>
- No:22584
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:31
-
Connect with a straight cable using a hub. For more details, refer to the following manual. - FL-net (OPCN-2) Interface Module User's Manual More Details >>
- No:22574
- Release Date:2018/09/03 17:29
- Update:2018/09/20 16:55