- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC-Q Series
FAQ
Keyword Search
FAQ within [ MELSEC-Q Series ]
-
Communication between Ethernet and FL-net
The communication between the Ethernet interface module and FL-net (OPCN-2) interface module cannot be established. More Details >>
- No:22683
- Release Date:2018/09/03 17:29
-
Difference between redundant systems and the multiple CPU systems
- Redundant systems A redundant system offers improved system reliability, as it consists of two basic systems, each of which includes a CPU module, powe... More Details >>
- No:22609
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:14
-
Difference between GX Works2 and GX Works
GX Works2 is programmable controller engineering software integrating programming and simulation of programmable controller and setting monitor tool functio... More Details >>
- No:22505
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:16
-
How to specify intelligent function module devices
For "U**", set the first two digits of the start I/O number of an intelligent function module in three-digit representation.Example) For X/Y1F0, set "U1F". More Details >>
- No:22704
- Release Date:2018/09/03 17:29
-
Compatibility between the A series modules and Q series modules
When an ACPU module is replaced with a QCPU module, programs for the ACPU module can be used by changing the PLC type in GX Developer. However, the programs ... More Details >>
- No:22696
- Release Date:2018/09/03 17:29
- Update:2018/09/21 14:21
-
This occurs because software required to display the Help window is not installed as standard in Windows7. Download the Windows Help program (WinHlp32.exe) f... More Details >>
- No:22674
- Release Date:2018/09/03 17:29
-
Battery life in the universal model QCPU
It depends on the model of the CPU module, the amount of battery consumption, and the power-on time ratio. Example) For Q06UDHCPU with power-on time ratio... More Details >>
- No:22633
- Release Date:2018/09/03 17:29
- Update:2018/09/21 11:28
-
Cause of file register reset by latch clear operation in universal model QCPU
If Latch (1) is set in the device setting of PLC parameter, the contents of file registers are cleared by latch clear operation. Set Latch (2) to maintain t... More Details >>
- No:22584
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:31
-
The automatic communication function and dedicated instructions (MBRW instruction and MBREQ instruction) can be used on the same channel. However, when the... More Details >>
- No:22577
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:06
-
How to turn OFF the "COM.ERR" LED of the Ethernet module
The LED can be turned OFF by operations from GX Developer. The operation method is as follows.(1) Connect to the CPU in the standby system in Transfer Setup.... More Details >>
- No:22571
- Release Date:2018/09/03 17:29