Set as follows in the Transfer Setup window. - Select "USB" for "PC side I/F". - Select "GOT" for "PLC side I/F" and select "via GOT (direct coupled) tra... More Details >>
- No:22598
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:55
-
Socket communication with the built-in Ethernet port of a CPU module
The communication between programmable controllers can be established using the socket communication function instructions. More Details >>
- No:22596
- Release Date:2018/09/03 17:29
-
It is an embedded RTOS (real-time OS) developed by Wind River, which is proven worldwide as reliable and stable.The version of the operation system installed... More Details >>
- No:22544
- Release Date:2018/09/03 17:28
-
Difference between C Controller module and programmable controller CPU module
- C Controller module: Programs are created using C and C++ languages. The programs run based on each task and parallel processing of multiple tasks base... More Details >>
- No:22542
- Release Date:2018/09/03 17:28
- Update:2018/09/20 15:05
-
It depends on the model of the CPU module, the amount of battery consumption, and the power-on time ratio.Example) For Q06HCPU with power-on time ratio of 50... More Details >>
- No:22523
- Release Date:2018/09/03 17:28
-
Ethernet system configuration of a redundant system
The following figure shows the basic configuration. When a control system Ethernet module is faulty or disconnected, the system is switched at a disco... More Details >>
- No:22718
- Release Date:2018/09/03 17:29
- Update:2018/09/18 11:45
-
GX Configurator-MB for the MODBUS(R) interface module
GX Configurator-MB does not need to be purchased. Parameters can be set using GX Works2 alone. More Details >>
- No:22701
- Release Date:2018/09/03 17:29
-
How to check automatically assigned devices in GX Works2
Click the local label to be checked and select "Cross Reference" from the right-click menu to check the devices. More Details >>
- No:22700
- Release Date:2018/09/03 17:29
-
You can use the output change upper limit value and the MV upper/lower limit limiter, the functions common to each PID control tag. Set the following parame... More Details >>
- No:22724
- Release Date:2018/09/03 17:29
- Update:2018/09/26 16:40
-
This occurs because software required to display the Help window is not installed as standard in Windows7. Download the Windows Help program (WinHlp32.exe) f... More Details >>
- No:22674
- Release Date:2018/09/03 17:29