Speeds of access to file registers
If file registers are registered in the standard RAM and "R" is specified by an instruction, the processing time is the same as is the case with the internal... More Details >>
- No:22688
- Release Date:2018/09/03 17:29
-
Deleting GX Developer when installing GX Works2
GX Developer does not need deleting when GX Works2 is installed. More Details >>
- No:22670
- Release Date:2018/09/03 17:29
-
Q series device data held in the case of a power failure
The data in the devices assigned to Latch (1) or Latch (2) in the "Device Setting" window ([PLC Parameter] -> [Device Setting] window) is held when a pow... More Details >>
- No:22638
- Release Date:2018/09/03 17:29
- Update:2018/09/21 11:37
-
MODBUS(R) interface module's involvement in master and slave stations
Intelligent function module settings allow them to be set in both master and slave stations. More Details >>
- No:22637
- Release Date:2018/09/03 17:29
-
Operation error at the execution of a BIN instruction
Keep SM722 ON or correct the program so that any one of the ten numbers 0 to 9 is stored in each digit of the source data.An operation error occurs when data... More Details >>
- No:22635
- Release Date:2018/09/03 17:29
-
CPU modules that support the File Register Extended Setting
The universal model QCPU modules other than Q00UJCPU support the File Register Extended Setting. More Details >>
- No:22627
- Release Date:2018/09/03 17:29
-
COMMENT to disappear after a PLC type change
Copy the COMMENT into the MAIN of comments by program before changing the PLC type.The basic model QCPU cannot deal with common comments. More Details >>
- No:22625
- Release Date:2018/09/03 17:29
-
GX Works2's compatibility with the A series modules
GX Developer is automatically launched when A series is selected as a new project in GX Works2.For the A series modules, use GX Developer. More Details >>
- No:22594
- Release Date:2018/09/03 17:29
-
Life expectancy of the CompactFlash card used in the high speed data logger module
The life expectancy is determined by the following calculation.Life expectancy (year) = Total writable size (GB) / 1 year write size (GB/year)For more detail... More Details >>
- No:22592
- Release Date:2018/09/03 17:29
-
How to read device data and file registers in Q series
Specify the target memory in the Read from PLC window and execute reading. More Details >>
- No:22564
- Release Date:2018/09/03 17:29