QCPU built-in Ethernet port setting when using the simple PLC communication function
The following settings are required for the "Open Setting" for the number of connected external devices. - Protocol: "UDP" - Open System: "MELSOFT connecti... More Details >>
- No:22654
- Release Date:2018/09/03 17:29
- Update:2018/09/21 12:02
-
You can use the output change upper limit value and the MV upper/lower limit limiter, the functions common to each PID control tag. Set the following parame... More Details >>
- No:22724
- Release Date:2018/09/03 17:29
- Update:2018/09/26 16:40
-
Difference between Q61P and Q64PN
There are differences in 5 VDC rated output current and in 5 VDC overcurrent protection.The difference in 5 VDC rated output current is as follows.- Q61P: 6 ... More Details >>
- No:22518
- Release Date:2018/09/03 17:28
-
Network No., Group No., and Station No. in Network Parameter
- Network No. is a number assigned to identify each network when multiple networks are configured. Each network No. must be unique. - Group No. is a num... More Details >>
- No:22550
- Release Date:2018/09/03 17:28
- Update:2018/09/20 15:48
-
What to do in the case of the error "A default router IP address needs to be set."
When having access bypassing a router, enter only the IP address.The subnet mask pattern is not required to be entered because GX Works2 or GX Developer auto... More Details >>
- No:22605
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:06
-
Operation error at the execution of a BIN instruction
Keep SM722 ON or correct the program so that any one of the ten numbers 0 to 9 is stored in each digit of the source data.An operation error occurs when data... More Details >>
- No:22635
- Release Date:2018/09/03 17:29
-
Cost of runtime licenses for VxWorks
The cost is included in the price of C Controller modules. Extra payment is not required. More Details >>
- No:22653
- Release Date:2018/09/03 17:29
-
How to check the capacity of the file registers in use
The capacity file registers currently have can be checked in the file register setting section ([PLC Parameter] -> [PLC File] tab). More Details >>
- No:22694
- Release Date:2018/09/03 17:29
- Update:2018/09/21 14:19
-
Updating to the 64-bit Windows 7 version of GX Works2
The message is displayed because the version of the CD does not support the 64-bit version. Execute the installation procedure in the condition. More Details >>
- No:22513
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:38
-
Behavior of special relay in simulation
The constant scan initial value in the simulation function is 100ms. Thus, the value of SM410(0.1sec. clock) is OFF in each scan. To turn ON/OFF SM410, set ... More Details >>
- No:22521
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:23