Updating to the 64-bit Windows 7 version of GX Works2
The message is displayed because the version of the CD does not support the 64-bit version. Execute the installation procedure in the condition. More Details >>
- No:22513
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:38
-
Fixed scan execution type (program setting item)
A fixed scan execution type program is a program executed at specified time intervals. This type of programs, unlike interrupt programs, can be interrupted i... More Details >>
- No:22617
- Release Date:2018/09/03 17:29
-
Parameter settings required to use the MODBUS(R) interface module as a slave station
If preset initial values are used, parameters do not need setting.If changing the basic parameter or MODBUS(R) device assignment parameter, use a sequence pr... More Details >>
- No:22680
- Release Date:2018/09/03 17:29
-
USB driver installation procedure
For the USB driver installation procedure, refer to the following manuals.- GX Developer Version 8 Operating Manual (Startup) Chapter 3- GX Works2 Version 1 ... More Details >>
- No:22502
- Release Date:2018/09/03 17:28
-
Network No., Group No., and Station No. in Network Parameter
- Network No. is a number assigned to identify each network when multiple networks are configured. Each network No. must be unique. - Group No. is a num... More Details >>
- No:22550
- Release Date:2018/09/03 17:28
- Update:2018/09/20 15:48
-
How to display local comments in GX Works2
In the "Reference/Reflection Target for Device Comment" window, switch the "Specify the Reference/Reflection" from "Global" to "Local". More Details >>
- No:22630
- Release Date:2018/09/03 17:29
-
Intelligent function module settings in GX Works2
Modules do not need setting in GX Works2 if not selectable from "Module Selection" in the "New Module" window for intelligent function module settings. More Details >>
- No:22685
- Release Date:2018/09/03 17:29
-
Make sure to turn off the power of the programmable controller before replacing the battery. Replacing the battery while the power of the programmable con... More Details >>
- No:22509
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:24
-
Cause of file register reset by latch clear operation in universal model QCPU
If Latch (1) is set in the device setting of PLC parameter, the contents of file registers are cleared by latch clear operation. Set Latch (2) to maintain t... More Details >>
- No:22584
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:31
-
Setting of Q series registers whose data is held when a power failure occurs
Assign data registers (D) to Latch (1) or Latch (2) in the "Device Setting" window ([PLC Parameter] -> "Device Setting" window) to hold the data when a po... More Details >>
- No:22601
- Release Date:2018/09/03 17:29