The following Diatrend cable can be used.- DQ-U2 More Details >>
- No:22623
- Release Date:2018/09/03 17:29
-
QnA-compatible 3E frame command (0406) for the built-in Ethernet port QCPU
The built-in Ethernet port QCPU is not compatible with a multiple-block batch read command (0406) of the MC protocol. Executable commands are the following.... More Details >>
- No:22608
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:09
-
CF cards supported by the high speed data logger module
For applicable CF cards, refer to the latest version of the following manual.- High Speed Data Logger Module User's Manual- SH-080818ENG- 2.3 Connection Syst... More Details >>
- No:22607
- Release Date:2018/09/03 17:29
-
How to turn OFF the "COM.ERR" LED of the Ethernet module
The LED can be turned OFF by operations from GX Developer. The operation method is as follows.(1) Connect to the CPU in the standby system in Transfer Setup.... More Details >>
- No:22571
- Release Date:2018/09/03 17:29
-
Difference between FL-net interface modules QJ71FL71-T and QJ71FL71-T-F01
- QJ71FL71-T is a product which supports FL-net (OPCN-2) Version 1.00.- QJ71FL71-T-F01 is a product which supports FL-net (OPCN-2) Version 2.00.Since Version... More Details >>
- No:22551
- Release Date:2018/09/03 17:28
-
Difference between QH42P and QX41Y41P
The difference is I/O numbers used for input and output (XY). QH42P uses the same I/O numbers both for input and output. QX41Y41P uses sequential I/O numbers... More Details >>
- No:22539
- Release Date:2018/09/03 17:28
-
Copying device comments in GX Developer
Open the copy destination project in GX Developer.From the menu, select [Project] -> [Copy], specify the copy source project, and check the device comment... More Details >>
- No:22519
- Release Date:2018/09/03 17:28
-
Pulse width with which the QX42 recognizes all pulses
Maximum scan time (10 ms) + Response time (10 ms) = Pulse width with which the module recognizes all pulses (20 ms) More Details >>
- No:22720
- Release Date:2018/09/03 17:29
-
How to check the capacity of the file registers in use
The capacity file registers currently have can be checked in the file register setting section ([PLC Parameter] -> [PLC File] tab). More Details >>
- No:22694
- Release Date:2018/09/03 17:29
- Update:2018/09/21 14:19
-
Print settings of the device list in GX Works2
When [Display Option] -> [Used devices] -> [Contact] and [Coil] are selected in the Device List window, devices used are not displayed. More Details >>
- No:22661
- Release Date:2018/09/03 17:29
- Update:2018/09/21 12:18