Heat generation of Q61P power supply module
Since the conversion efficiency of the power supply module is approximately 70%, and 30% of the output power is dissipated as heat, the power consumption is ... More Details >>
- No:22529
- Release Date:2018/09/03 17:28
-
You can use the output change upper limit value and the MV upper/lower limit limiter, the functions common to each PID control tag. Set the following parame... More Details >>
- No:22724
- Release Date:2018/09/03 17:29
- Update:2018/09/26 16:40
-
Hardware setting for using Q series extension base units
You need to set the number of extension base units with the connector for setting the number of extension base units.For details, refer to the following.SH-0... More Details >>
- No:22721
- Release Date:2018/09/03 17:29
-
Change timing of the status of A/D conversion module's I/O signals
(1)If the A/D conversion enable signal is kept ON, conversion processing is kept performed. Once conversion processing is successfully performed, A/D conve... More Details >>
- No:22710
- Release Date:2018/09/03 17:29
- Update:2018/09/21 15:12
-
Replacing personal computers with C Controller modules
The merits are as follows. (1) Downsized device The volume ratio is 1 to 10 in comparison with the VME card rack (6U) type. (2) Long-term stable supply... More Details >>
- No:22706
- Release Date:2018/09/03 17:29
- Update:2018/09/21 14:33
-
Whether or not totem pole output type encoders are connected
Totem pole output encoders cannot be connected to QD62.The following types of encoders can be connected.- Open collector output type encoders- CMOS level vol... More Details >>
- No:22641
- Release Date:2018/09/03 17:29
-
Creating comments both in English and in Japanese
Create global device comments and local device comments in respective languages.The device comments can be switched in [Options] -> [Tool]. More Details >>
- No:22620
- Release Date:2018/09/03 17:29
-
Reading file registers simultaneously with the program, parameters, and other data in GX Works2
No. Switch the target memory for PLC Data and read the file registers alone. More Details >>
- No:22616
- Release Date:2018/09/03 17:29
-
Ethernet system configuration of a redundant system
The following figure shows the basic configuration. When a control system Ethernet module is faulty or disconnected, the system is switched at a disco... More Details >>
- No:22718
- Release Date:2018/09/03 17:29
- Update:2018/09/18 11:45