- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC-Q Series
FAQ
Keyword Search
FAQ within [ MELSEC-Q Series ]
-
Insufficient memory capacity for sequence programs
It cannot be increased by installing an SRAM card. The size of executable program depends on the program memory size of the CPU. Use another CPU of which p... More Details >>
- No:22578
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:09
-
GX Developer's compatibility with 64-bit Windows 7
GX Developer Version 8.98C or later supports 64-bit Windows 7. To install GX Developer to a Windows 7-based personal computer, refer to the following techni... More Details >>
- No:22501
- Release Date:2018/09/03 17:28
- Update:2018/09/20 12:19
-
The error code "2401" is "FILE SET ERROR". The individual information parameter number "1100H" corresponds to a file register. The cause of the error is th... More Details >>
- No:22535
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:46
-
Difference between SM0 and SM1
SM0 turns ON when self-diagnostic checks detect an error or when an annunciator turns ON.SM1 turns ON when self-diagnostic checks detect an error. More Details >>
- No:22632
- Release Date:2018/09/03 17:29
-
Grounding FG and LG terminals of power supply module
Both of them need to be grounded. They can be shorted and grounded as one cable. More Details >>
- No:22527
- Release Date:2018/09/03 17:28
-
The error code "2110" is "SP.UNIT ERROR.". This error may be caused by one of the following factors. (1) The module that has been specified by a FROM/TO i... More Details >>
- No:22662
- Release Date:2018/09/03 17:29
- Update:2018/09/21 13:48
-
Turning ON/OFF annunciators (F)
The data in the special registers SD62 to SD79 change with the following process. - Turn ON the registers with OUT and SET instructions. - Turn OFF the r... More Details >>
- No:22649
- Release Date:2018/09/03 17:29
- Update:2018/09/21 11:45
-
How to read the device memory in GX Works2
Select [Online] -> [Read from PLC] from the menu and check "Device Memory" in the file list in the window and then execute PLC read. More Details >>
- No:22621
- Release Date:2018/09/03 17:29
-
The error code "2400" is "FILE SET ERROR".It may be determined as the cause of the error that the file that has been specified by a parameter does not exist.... More Details >>
- No:22703
- Release Date:2018/09/03 17:29
-
Error in simulation in GX Works2
This problem can be workarounded by upgrading software products made by other companies to the latest version or uninstalling them.For more details, refer to... More Details >>
- No:22570
- Release Date:2018/09/03 17:29
11-20 of Total 213