  • How to clear errors

    Follow the procedure below.(1)Eliminate the error cause.(2) Store the error code to be cleared in SD50.(3)Turn OFF and ON SM50.(4) The error is cleared. More Details >>

    • No:22613
    • Release Date:2018/09/03 17:29
  • How to open GX Works2 projects in GX Developer

    Select "Project" -> "Export to GX Developer Format File" from the menu of GX Works2 to save the project in the format that can be opened in GX Developer. More Details >>

    • No:22514
    • Release Date:2018/09/03 17:28
    • Update:2018/09/20 13:40
  • Error code "2400" in QCPU

    The error code "2400" is "FILE SET ERROR".It may be determined as the cause of the error that the file that has been specified by a parameter does not exist.... More Details >>

    • No:22703
    • Release Date:2018/09/03 17:29
  • Error code "2110" in QCPU

    The error code "2110" is "SP.UNIT ERROR.". This error may be caused by one of the following factors. (1) The module that has been specified by a FROM/TO i... More Details >>

    • No:22662
    • Release Date:2018/09/03 17:29
    • Update:2018/09/21 13:48
  • Error code "2401" in QCPU

    The error code "2401" is "FILE SET ERROR". The individual information parameter number "1100H" corresponds to a file register. The cause of the error is th... More Details >>

    • No:22535
    • Release Date:2018/09/03 17:28
    • Update:2018/09/20 14:46
  • USB driver installation

    Yes. A USB driver needs to be installed.For the installation procedure, refer to the following manual. - GX Developer Version 8 Operating Manual (Startup) More Details >>

    • No:22504
    • Release Date:2018/09/03 17:28
    • Update:2018/09/20 13:10
  • Error code "2200" in the universal model QCPU

    The error code "2200" is "MISSING PARA.". The cause of the error is that a parameter file does not exist in all drives where parameters will be valid.As a re... More Details >>

    • No:22614
    • Release Date:2018/09/03 17:29
  • When the message "An unusable COM port was specified" is displayed

    RS-232 is selected as PC side I/F in Transfer Setup of GX Developer or GX Works2.Change the setting in PC side I/F to USB. More Details >>

    • No:22517
    • Release Date:2018/09/03 17:28
  • GX Works2's USB driver installation procedure

    The USB driver is not installed.The driver needs to be separately installed before the first connection to a CPU module. More Details >>

    • No:22507
    • Release Date:2018/09/03 17:28
  • Error code "2100" in QCPU

    The error code "2100" is "SP.UNIT LAY ERR.". This error may be caused by one of the following factors. (1) In the I/O assignment setting of the PLC parame... More Details >>