FAQ within [ MELSEC-Q Series ]
-
Ethernet system configuration of a redundant system
The following figure shows the basic configuration. When a control system Ethernet module is faulty or disconnected, the system is switched at a disco... More Details >>
- No:22718
- Release Date:2018/09/03 17:29
- Update:2018/09/18 11:45
-
Programing example of heating/cooling control
The following shows an example of heating/cooling control using split control. * For details, refer to the "Programmable Controllers MELSEC PROC... More Details >>
- No:22719
- Release Date:2018/09/03 17:29
- Update:2018/09/21 15:43
-
Hardware setting for using Q series extension base units
You need to set the number of extension base units with the connector for setting the number of extension base units.For details, refer to the following.SH-0... More Details >>
- No:22721
- Release Date:2018/09/03 17:29
-
Boot operation from the standard ROM
The boot operation from the standard ROM is not possible.The program memory of universal model QCPU is a flash ROM.Thus, writing in the program memory achiev... More Details >>
- No:22553
- Release Date:2018/09/03 17:28
-
Battery replacement for High-Performance model QCPU
The contents of the program memory, the standard RAM, and latch devices are not erased if the battery replacement is completed within three minutes, which is... More Details >>
- No:22568
- Release Date:2018/09/03 17:29
-
The model name of Japanese version is SW[ ]D5C-SHEETSET-J and that of English version is SW[ ]D5C-SHEETSET-E. More Details >>
- No:22580
- Release Date:2018/09/03 17:29
-
Life expectancy of the CompactFlash card used in the high speed data logger module
The life expectancy is determined by the following calculation.Life expectancy (year) = Total writable size (GB) / 1 year write size (GB/year)For more detail... More Details >>
- No:22592
- Release Date:2018/09/03 17:29
-
GX Works2's compatibility with the A series modules
GX Developer is automatically launched when A series is selected as a new project in GX Works2.For the A series modules, use GX Developer. More Details >>
- No:22594
- Release Date:2018/09/03 17:29
-
CF cards supported by the high speed data logger module
For applicable CF cards, refer to the latest version of the following manual.- High Speed Data Logger Module User's Manual- SH-080818ENG- 2.3 Connection Syst... More Details >>
- No:22607
- Release Date:2018/09/03 17:29
-
Reading file registers simultaneously with the program, parameters, and other data in GX Works2
No. Switch the target memory for PLC Data and read the file registers alone. More Details >>
- No:22616
- Release Date:2018/09/03 17:29