MX Component Version 3's compatibility with 64-bit Windows 7
MX Component Version 3.15R or later supports 64-bit Windows 7. More Details >>
- No:22520
- Release Date:2018/09/03 17:28
-
Error in simulation in GX Works2
This problem can be workarounded by upgrading software products made by other companies to the latest version or uninstalling them.For more details, refer to... More Details >>
- No:22570
- Release Date:2018/09/03 17:29
-
Simulation function not started
The simulation function utilizes the standard TCP/IP communication provided by Microsoft Corporation. A communication capability of software of another make... More Details >>
- No:22631
- Release Date:2018/09/03 17:29
- Update:2018/09/21 10:45
-
How to read comments in the standard ROM with GX Works2
Select [Target Memory] -> [Standard ROM] in the Read from PLC window. More Details >>
- No:22673
- Release Date:2018/09/03 17:29
- Update:2018/09/21 14:05
-
Boot file setting of the QnUDVCPU
No. You cannot use an SRAM card, ATA card, or Flash card. Specify an SD memory card as the transfer source (boot source). More Details >>
- No:22714
- Release Date:2018/09/03 17:29
-
Difference between Q24DHCCPU-V and Q12DCCPU-V
Hardware specifications are different. For hardware specifications, refer to the following manuals. - MELSEC-Q C Controller Module User's Manual - C Contro... More Details >>
- No:22629
- Release Date:2018/09/03 17:29
- Update:2018/09/21 10:41
-
Making transparent connections using GX Developer
Set as follows in the Transfer Setup window. - Select "USB" for "PC side I/F". - Select "CPU Module" for "PLC side I/F" and check "via GOT (direct couple... More Details >>
- No:22640
- Release Date:2018/09/03 17:29
- Update:2018/09/21 11:39
-
Behavior of special relay in simulation
The constant scan initial value in the simulation function is 100ms. Thus, the value of SM410(0.1sec. clock) is OFF in each scan. To turn ON/OFF SM410, set ... More Details >>
- No:22521
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:23
-
COMMENT to disappear after a PLC type change
Copy the COMMENT into the MAIN of comments by program before changing the PLC type.The basic model QCPU cannot deal with common comments. More Details >>
- No:22625
- Release Date:2018/09/03 17:29
-
Accessible numbers of devices in one message are shown below.- 2000 coils and inputs for reading- 125 input registers and holding registers for reading- 1968... More Details >>