FAQ


FAQAbout Products

- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC-L Series
FAQ
Keyword Search
FAQ within [ MELSEC-L Series ]
-
Use of 4E frame for built-in Ethernet port of LCPU
The built-in Ethernet port in the L series is compatible only with the QnA-compatible 3E frame. The 4E frame is not supported. More Details >>
- No:22761
- Release Date:2018/09/03 17:30
-
Simultaneous broadcast transmission setting for built-in Ethernet port LCPU
To send simultaneous broadcast using UDP, set the parameters as follows.- Destination IP Address: FF.FF.FF.FFh - Destination Port Number: Other than FFFFh (S... More Details >>
- No:22785
- Release Date:2018/09/03 17:30
-
Built-in positioning function of LCPU
The positioning operation starts just in 30 microseconds, with a maximum high speed output of 200k pulses per second. S-curve acceleration/deceleration is al... More Details >>
- No:22790
- Release Date:2018/09/03 17:30
-
Number of points used for I/O assignment of LCPU built-in I/O function
X00 to X0F and Y00 to Y07 are sorted for each function. For more details, refer to "MELSEC-L CPU Module User's Manual (Built-In I/O Function)". More Details >>
- No:22762
- Release Date:2018/09/03 17:30
-
Indication accuracy - Ambient temperature: 25+/-5 degrees Celsius Full scale x (+/-0.3%) - Ambient temperature: 0 to 55degrees Celsius Full scale x (+/-0... More Details >>
- No:22820
- Release Date:2018/09/03 17:30
- Update:2018/09/26 16:51
-
Method to prevent the BAT.LED from turning on
To prevent an LED from turning on when an error occurs, set 0 to the relevant factor number setting area (4 bits for each) in SD207 to SD209. To disable the ... More Details >>
- No:22754
- Release Date:2018/09/03 17:29
-
SD1284 of LCPU with built-in Ethernet port
The bits 0 to F of the special register SD1284 (Open request signal) correspond to the connection numbers 1 to 16. When the open request is sent, the corresp... More Details >>
- No:22784
- Release Date:2018/09/03 17:30
-
Remedy to an error message when performing online change in LCPU
After data is written to the program cache memory (SRAM), it is automatically transferred to the program memory (flash ROM). Therefore, additional online cha... More Details >>
- No:22763
- Release Date:2018/09/03 17:30
- Update:2018/09/22 10:50
-
LCPU built-in Ethernet port setting when using the simple PLC communication function
The following settings are required for the "Open Setting" for the number of connected external devices.- Protocol: "UDP"- Open System: "MELSOFT connection" More Details >>
- No:22739
- Release Date:2018/09/03 17:29
-
Boot operation from the standard ROM
The boot operation from the standard ROM is not possible. The program memory of LCPU is a flash ROM. Thus, writing in the program memory achieves a ROM opera... More Details >>
- No:22728
- Release Date:2018/09/03 17:29