Simultaneous use of simple PLC communication function and socket communication
The socket communication can be used simultaneously with the simple PLC communication function. More Details >>
- No:22740
- Release Date:2018/09/03 17:29
-
Availability of step ladders for FX in L series
Step ladders are not available in LCPU. There is no alternative function. More Details >>
- No:22752
- Release Date:2018/09/03 17:29
-
LCPU internal clock synchronization
Use the time setting function to synchronize the internal clock. More Details >>
- No:22755
- Release Date:2018/09/03 17:30
-
How to use PWM output of LCPU built-in I/O
Set the PWM output-on-width and the PWM output cycle, and then execute a dedicated instruction "ICPWM instruction". More Details >>
- No:22757
- Release Date:2018/09/03 17:30
-
Number of points used for I/O assignment of LCPU built-in I/O function
X00 to X0F and Y00 to Y07 are sorted for each function. For more details, refer to "MELSEC-L CPU Module User's Manual (Built-In I/O Function)". More Details >>
- No:22762
- Release Date:2018/09/03 17:30
-
Remedy to an error message when performing online change in LCPU
After data is written to the program cache memory (SRAM), it is automatically transferred to the program memory (flash ROM). Therefore, additional online cha... More Details >>
- No:22763
- Release Date:2018/09/03 17:30
- Update:2018/09/22 10:50
-
PLC write not possible due to memory overload
If comments cannot be stored in the program memory, write them in the standard ROM or a memory card. Calculate the memory capacity in GX Works2 or GX Develop... More Details >>
- No:22767
- Release Date:2018/09/03 17:30
-
Versions of built-in Ethernet port LCPU compatible with SNTP function
The initial version and subsequent versions of L series CPU support the SNTP function. More Details >>
- No:22769
- Release Date:2018/09/03 17:30
-
Simultaneous broadcast reception setting for built-in Ethernet port LCPU
To receive simultaneous broadcast using UDP, set the parameters as follows. - Destination IP Address: FF.FF.FF.FFh - Destination Port No.: Other than FFFFh (... More Details >>
- No:22772
- Release Date:2018/09/03 17:30
-
Number of points used for I/O assignment of L26CPU-(P)BT built-in CC-Link function
It is fixed to 32 points from 10 to 2F. More Details >>
- No:22777
- Release Date:2018/09/03 17:30