Use of an A-compatible 1E frame for the built-in Ethernet port of LCPU
The built-in Ethernet port in the L series is compatible only with a QnA-compatible 3E frame of the MC protocol. An A-compatible 1E frame is not supported. More Details >>
- No:22731
- Release Date:2018/09/03 17:29
-
The contents of the standard RAM and latch devices are not erased if the battery replacement is completed within three minutes, which is the backup power tim... More Details >>
- No:22733
- Release Date:2018/09/03 17:29
-
LCPU built-in Ethernet port setting when using the simple PLC communication function
The following settings are required for the "Open Setting" for the number of connected external devices.- Protocol: "UDP"- Open System: "MELSOFT connection" More Details >>
- No:22739
- Release Date:2018/09/03 17:29
-
No. It is necessary to configure one port to use the MELSOFT connection. More Details >>
- No:22765
- Release Date:2018/09/03 17:30
-
Execution of the SOCRMODE instruction in the same connection during socket communication of LCPU
It can be executed for the same connection number. When data exist in the socket communication receive data area and the SOCRMODE instruction is executed, va... More Details >>
- No:22771
- Release Date:2018/09/03 17:30
-
Cable length to connect to built-in Ethernet port in LCPU
The maximum length between a hub and a node is 100 m. The max. length connectable to a hub is 200m.When repeater hubs are used in cascade connection, the max... More Details >>
- No:22781
- Release Date:2018/09/03 17:30
-
Indication accuracy - Ambient temperature: 25+/-5 degrees Celsius Full scale x (+/-0.3%) - Ambient temperature: 0 to 55degrees Celsius Full scale x (+/-0... More Details >>
- No:22820
- Release Date:2018/09/03 17:30
- Update:2018/09/26 16:51
-
CPU operation when the time setting failed
When an error occurs, the operation can be stopped or continued according to the "At Error Occurrence" setting.(The default is "Continue".) More Details >>
- No:22828
- Release Date:2018/09/03 17:30
-
Communication data code of the MC protocol for the built-in Ethernet port in LCPU
The communication data code is selectable by the communication data code setting in [Parameter] -> [PLC Parameter] -> [Built-in Ethernet Port Setting]. More Details >>
- No:22735
- Release Date:2018/09/03 17:29
- Update:2018/09/21 17:22
-
Difference between L02CPU-P and L02CPU
In L02CPU-P, the general-purpose output of the built-in I/O is source type. In L02CPU, the general-purpose output of the built-in I/O is sink type. More Details >>