FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC-L Series
FAQ
Keyword Search
FAQ within [ MELSEC-L Series ]
-
Battery install position in LCPU
Open the cover at the bottom of the CPU module and install the battery. More Details >>
- No:22821
- Release Date:2018/09/03 17:30
-
Up to 10 modules are connectable. Note that RS-232 adapter and END cover are excluded. Use the built-in CC-Link function for I/O enhancement. More Details >>
- No:22802
- Release Date:2018/09/03 17:30
-
Logging data storage in a USB memory
GX LogViewer function of Mitsubishi GOT (GT16) extracts the logging data to a USB memory attached to the USB interface on the front of the GOT. More Details >>
- No:22730
- Release Date:2018/09/03 17:29
-
Precautions for insertion and removal of SD memory card
Turn off the SD memory card switch and check that the LED indicator is off before insertion or removal of an SD memory card. More Details >>
- No:22818
- Release Date:2018/09/03 17:30
-
Built-in positioning function of LCPU
The positioning operation starts just in 30 microseconds, with a maximum high speed output of 200k pulses per second. S-curve acceleration/deceleration is al... More Details >>
- No:22790
- Release Date:2018/09/03 17:30
-
CPU clock setting by SNTP functions via built-in Ethernet port in LCPU
The clock setting of the CPU module is set automatically in accordance with the clock data collected from the time information server (SNTP server) on the LAN. More Details >>
- No:22736
- Release Date:2018/09/03 17:29
-
No. It is necessary to configure one port to use the MELSOFT connection. More Details >>
- No:22765
- Release Date:2018/09/03 17:30
-
They can be used simultaneously when I/O signals are not overlapped. The overlap of signals are checked automatically when a user select functions in the bui... More Details >>
- No:22816
- Release Date:2018/09/03 17:30
-
Communication data code of the MC protocol for the built-in Ethernet port in LCPU
The communication data code is selectable by the communication data code setting in [Parameter] -> [PLC Parameter] -> [Built-in Ethernet Port Setting]. More Details >>
- No:22735
- Release Date:2018/09/03 17:29
- Update:2018/09/21 17:22
-
Alive check for built-in Ethernet port LCPU
When the protocol is set to TCP, KeepAlive check is performed. (Checking for a response to KeepAlive ACK message) An alive check message is sent five seconds... More Details >>
- No:22782
- Release Date:2018/09/03 17:30
51-60 of Total 105