- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC-L Series
FAQ
Keyword Search
FAQ within [ MELSEC-L Series ]
-
Configuration of simple PLC communication function using LCPU
At least one L series CPU is necessary when using the simple PLC communication function. More Details >>
- No:22747
- Release Date:2018/09/03 17:29
-
CPU operation when the time setting failed
When an error occurs, the operation can be stopped or continued according to the "At Error Occurrence" setting.(The default is "Continue".) More Details >>
- No:22828
- Release Date:2018/09/03 17:30
-
Yes. As a guide, the processing time is shown below.For the logging condition, refer to figure 1 below. - For 16 devices: 2 ms - For 64 devices: 6 ms More Details >>
- No:22829
- Release Date:2018/09/03 17:30
- Update:2018/09/22 15:33
-
Simultaneous broadcast transmission setting for built-in Ethernet port LCPU
To send simultaneous broadcast using UDP, set the parameters as follows.- Destination IP Address: FF.FF.FF.FFh - Destination Port Number: Other than FFFFh (S... More Details >>
- No:22785
- Release Date:2018/09/03 17:30
-
- Ambient temperature: 25+/-5degrees Celsius Full scalex (+/-0.3%) - Ambient temperature: 0 to 55degrees Celsius Full scalex (+/-0.7%) More Details >>
- No:22823
- Release Date:2018/09/03 17:30
- Update:2018/09/27 11:35
-
How to obtain connectors used for L series connector type I/O modules
A connector is not included. The connector is obtained by user. A6CON1 (soldering connector, straight out type), A6CON2 (crimp connector, straight out type),... More Details >>
- No:22791
- Release Date:2018/09/03 17:30
-
Precautions for use of SD memory card
Yes. Note that SD memory cards are formatted at the factory. If an SD memory card needs to be reformatted, format it using the CPU module. More Details >>
- No:22779
- Release Date:2018/09/03 17:30
-
Connection status detection between a hub and the built-in Ethernet port of LCPU
The bit 10 of the special register SD1288 provides the connection status to a hub. When the bit 10 of SD1288 is ON, a hub is connected. More Details >>
- No:22759
- Release Date:2018/09/03 17:30
-
The data logging file transfer function allows for transfer of the logging data to an upper server regularly. It is transferred when data logging is switched... More Details >>
- No:22741
- Release Date:2018/09/03 17:29
-
Resolution provided for L60AD4
The maximum resolution for the user range setting does not change. More Details >>
- No:22827
- Release Date:2018/09/03 17:30
- Update:2018/09/22 15:24