- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC-L Series
FAQ
Keyword Search
FAQ within [ MELSEC-L Series ]
-
CSV file storage timing in L series logging function
No. More Details >>
- No:22793
- Release Date:2018/09/03 17:30
-
How to use LCPU connector terminals
The LCPU connector terminals can be used as terminals for built-in I/O function. The setting of the built-in I/O function can be configured with the paramete... More Details >>
- No:22796
- Release Date:2018/09/03 17:30
-
I/O assignment for additional modules connected to LCPU
In L02CPU(-P), the start I/O number of the additional module begins from 10H. In L26CPU-(P)BT, the number begins from 30H. More Details >>
- No:22808
- Release Date:2018/09/03 17:30
-
Connected position of branch module and extension module
The position to connect the branch module and extension module is as follows. More Details >>
- No:22814
- Release Date:2018/09/03 17:30
- Update:2018/09/22 15:27
-
CPU operation when the time setting failed
When an error occurs, the operation can be stopped or continued according to the "At Error Occurrence" setting.(The default is "Continue".) More Details >>
- No:22828
- Release Date:2018/09/03 17:30
-
LCPU built-in Ethernet port setting when using the simple PLC communication function
The following settings are required for the "Open Setting" for the number of connected external devices.- Protocol: "UDP"- Open System: "MELSOFT connection" More Details >>
- No:22739
- Release Date:2018/09/03 17:29
-
TCP retransmission timer setting for built-in Ethernet port LCPU
For the built-in Ethernet port in the L series CPU, the TCP retransmission timer setting is fixed and unchangeable. The retransmission occurs six times. The... More Details >>
- No:22745
- Release Date:2018/09/03 17:29
- Update:2018/09/21 17:52
-
KeepAlive setting for built-in Ethernet port in LCPU
The KeepAlive setting for the built-in Ethernet port in the L series is fixed. The setting is unchangeable. More Details >>
- No:22760
- Release Date:2018/09/03 17:30
-
Use of 4E frame for built-in Ethernet port of LCPU
The built-in Ethernet port in the L series is compatible only with the QnA-compatible 3E frame. The 4E frame is not supported. More Details >>
- No:22761
- Release Date:2018/09/03 17:30
-
Cable length to connect to built-in Ethernet port in LCPU
The maximum length between a hub and a node is 100 m. The max. length connectable to a hub is 200m.When repeater hubs are used in cascade connection, the max... More Details >>
- No:22781
- Release Date:2018/09/03 17:30