Remedy to an error message when performing online change in LCPU
After data is written to the program cache memory (SRAM), it is automatically transferred to the program memory (flash ROM). Therefore, additional online cha... More Details >>
- No:22763
- Release Date:2018/09/03 17:30
- Update:2018/09/22 10:50
-
Number of points used for I/O assignment of LCPU built-in I/O function
X00 to X0F and Y00 to Y07 are sorted for each function. For more details, refer to "MELSEC-L CPU Module User's Manual (Built-In I/O Function)". More Details >>
- No:22762
- Release Date:2018/09/03 17:30
-
How to use PWM output of LCPU built-in I/O
Set the PWM output-on-width and the PWM output cycle, and then execute a dedicated instruction "ICPWM instruction". More Details >>
- No:22757
- Release Date:2018/09/03 17:30
-
Behavior of sequence program in event of momentary power failure in LCPU
(1) When it happened no longer than the allowable momentary power failure time. The module records an error log and suspends the operation processing. Ho... More Details >>
- No:22756
- Release Date:2018/09/03 17:30
- Update:2018/09/22 10:43
-
LCPU internal clock synchronization
Use the time setting function to synchronize the internal clock. More Details >>
- No:22755
- Release Date:2018/09/03 17:30
-
Availability of step ladders for FX in L series
Step ladders are not available in LCPU. There is no alternative function. More Details >>
- No:22752
- Release Date:2018/09/03 17:29
-
The number of LCPU extension blocks
(1) The number of modules to be connected- Main block: up to 10 modules- Extension block: up to 11 modules(2) The number of extension blocks- L02CPU, L02CPU-... More Details >>
- No:22750
- Release Date:2018/09/03 17:29
-
Communication between CPUs via built-in Ethernet port in LCPU
The following communication methods are available between the built-in Ethernet ports in the L series CPUs.- Simple PLC communication function- Socket commun... More Details >>
- No:22746
- Release Date:2018/09/03 17:29
-
Simultaneous use of simple PLC communication function and socket communication
The socket communication can be used simultaneously with the simple PLC communication function. More Details >>
- No:22740
- Release Date:2018/09/03 17:29
-
Turning OFF the power with the battery error occurring
The error history will be deleted. More Details >>
- No:22734
- Release Date:2018/09/03 17:29