- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC-L Series
FAQ
Keyword Search
FAQ within [ MELSEC-L Series ]
-
The number of LCPU extension blocks
(1) The number of modules to be connected- Main block: up to 10 modules- Extension block: up to 11 modules(2) The number of extension blocks- L02CPU, L02CPU-... More Details >>
- No:22750
- Release Date:2018/09/03 17:29
-
Configuration of simple PLC communication function using LCPU
At least one L series CPU is necessary when using the simple PLC communication function. More Details >>
- No:22747
- Release Date:2018/09/03 17:29
-
LCPU built-in Ethernet port setting when using the simple PLC communication function
The following settings are required for the "Open Setting" for the number of connected external devices.- Protocol: "UDP"- Open System: "MELSOFT connection" More Details >>
- No:22739
- Release Date:2018/09/03 17:29
-
How to use L series extension modules
The extension module is used to configure the extension block when 10 modules or more are mounted to LCPU. Connect the branch module and the extension module... More Details >>
- No:22738
- Release Date:2018/09/03 17:29
-
MC protocol compatibility of the built-in Ethernet port
The built-in Ethernet port is not compatible with a 4E frame. Use a QnA-compatible 3E frame. More Details >>
- No:22732
- Release Date:2018/09/03 17:29
-
Logging data storage in a USB memory
GX LogViewer function of Mitsubishi GOT (GT16) extracts the logging data to a USB memory attached to the USB interface on the front of the GOT. More Details >>
- No:22730
- Release Date:2018/09/03 17:29
-
QnA-compatible 3E frame command for built-in Ethernet port in LCPU
The built-in Ethernet port in the L series CPU is not compatible with a multiple-block batch read command (0406) of the MC protocol. Executable commands are ... More Details >>
- No:22726
- Release Date:2018/09/03 17:29
-
The error code "2110" is "SP.UNIT ERROR.". This error may be caused by one of the following factors.(1) The module that has been specified by a FROM/TO instr... More Details >>
- No:22830
- Release Date:2018/09/03 17:30
-
CPU operation when the time setting failed
When an error occurs, the operation can be stopped or continued according to the "At Error Occurrence" setting.(The default is "Continue".) More Details >>
- No:22828
- Release Date:2018/09/03 17:30
-
The conversion speed is 20 microseconds per channel. More Details >>
- No:22826
- Release Date:2018/09/03 17:30
81-90 of Total 105