How to check errors in a CC-Link master station
When an error has occurred in the master station (including the standby master station), the data link control cannot be performed, and you cannot check erro... More Details >>
- No:23078
- Release Date:2018/09/03 17:31
-
The CC-Link remote I/O modules' model names represents as follows:- AJ65SBTB1 - S: Compact type - B1: 1-wire terminal block, 1-common type- AJ65SBTB2 - S:... More Details >>
- No:22994
- Release Date:2018/09/03 17:31
-
Data length for fixed buffer data communications by QJ71E71
The units of send data and receive data are shown below. - Fixed buffer data communications with the "Procedure Exist" control method: Words - Fixed buff... More Details >>
- No:23061
- Release Date:2018/09/03 17:31
- Update:2018/09/26 11:17
-
Precaution about MELSECNET/H connection (1)
- Set successive station numbers for the network modules in system A and system B in a redundant system. (Station number 0 cannot be set.) - Match "host... More Details >>
- No:23055
- Release Date:2018/09/03 17:31
- Update:2018/09/26 11:12
-
Overall cable distance and station-to-station distance in CC-Link networks
The overall cable distance and station-to-station distance depend on the version and the transmission speed. Figure 1 shows the case with Ver.1.10-compatibl... More Details >>
- No:23028
- Release Date:2018/09/03 17:31
- Update:2018/09/26 10:14
-
The CC-Link family products allow flexible programming and maintenance from any controllers for all the devices in connection. Such a communication, for whic... More Details >>
- No:23026
- Release Date:2018/09/03 17:31
-
CC-Link master module settings
If each master module controls their own CC-Link networks, all master modules can be set as station 0 even though they are controlled by the same CPU. More Details >>
- No:23008
- Release Date:2018/09/03 17:31
-
PLC parameter setting for QJ61BT11N
If the Network Parameter is used, CC-Link communication does not need the Select setting in the I/O assignment setting of the PLC parameter.If the parameter ... More Details >>
- No:23002
- Release Date:2018/09/03 17:31
-
Terminating resistors for RS-485 communication of LJ71C24
The resistance value is 110 ohm, 1/2 W. More Details >>
- No:22999
- Release Date:2018/09/03 17:31
- Update:2018/10/03 15:25
-
CC-Link master modules' start I/O No. and refresh devices RX/RY
The I/O numbers used for I/O modules and intelligent function modules cannot be used as refresh targets for RX/RY. Use the I/O numbers greater than those use... More Details >>
- No:22997
- Release Date:2018/09/03 17:31