How to check errors in a CC-Link master station
When an error has occurred in the master station (including the standby master station), the data link control cannot be performed, and you cannot check erro... More Details >>
- No:23078
- Release Date:2018/09/03 17:31
-
RS-485 connection between QJ71C24N and an external device
Short between SDA and RDA and between SDB and RDB, and then connect them to + (Data-A) and - (Data-B) on the external device. More Details >>
- No:22986
- Release Date:2018/09/03 17:31
-
Link register assignments in MELSECNET/10 networks
For any type of MELSECNET network (II, /10, and H), B and W devices with the same number cannot be used for multiple stations as write areas. Following th... More Details >>
- No:22971
- Release Date:2018/09/03 17:31
- Update:2018/09/25 13:24
-
Assignment for connecting two CC-Link remote input modules (16-point type) (Remote net Ver.1 mode)
X devices will be assigned as follows. (With this setting, 32 points are occupied per station.) - Station No. 1: X100 to X11F -Station No. 2: X120 to X13... More Details >>
- No:23082
- Release Date:2018/09/03 17:31
- Update:2018/09/26 13:15
-
Difference between AJ65SBTB1-32DTE1 and AJ65SBTB1-32DT1
Major differences are shown below. - AJ65SBTB1-32DT1 - Input type positive common (sink type) - Rated input current approx. 5 mA - ON voltage/ON curr... More Details >>
- No:23022
- Release Date:2018/09/03 17:31
- Update:2018/09/26 09:52
-
T-branch connection and star topology for CC-Link networks
- T-branch T-branch is a connection type that branches one line from a main line. To establish a T-branch CC-Link network, use the repeater module AJ65S... More Details >>
- No:23024
- Release Date:2018/09/03 17:31
- Update:2018/09/26 10:00
-
For CPU modules with 8192 I/O device points (X/Y0 to 1FFF), X/Y1000 and greater can be set as refresh devices. More Details >>
- No:23014
- Release Date:2018/09/03 17:31
-
Use a T-branch repeater module instead of a terminal block. More Details >>
- No:23086
- Release Date:2018/09/03 17:31
-
Differences between the AJ65SBTB1-16TE and AJ65SBTB1B-16TE1
The following shows the major differences. -AJ65SBTB1-16TE - 1-wire terminal block, 1-common type - Maximum load current: 0.1 A/point -Protection fu... More Details >>
- No:23083
- Release Date:2018/09/03 17:31
- Update:2018/09/26 13:16
-
SB/SW refresh device setting with CC-Link
There are no problems even though the SB/SW refresh device has not been set. More Details >>
- No:23080
- Release Date:2018/09/03 17:31