Parameter settings for a CC-Link master station and local stations
Local stations also need parameter settings. More Details >>
- No:22991
- Release Date:2018/09/03 17:31
-
The CC-Link remote I/O modules' model names represents as follows:- AJ65SBTB1 - S: Compact type - B1: 1-wire terminal block, 1-common type- AJ65SBTB2 - S:... More Details >>
- No:22994
- Release Date:2018/09/03 17:31
-
Settings required for transient transmission
The routing parameter settings are required for transient transmission to the CPU module with another network No. The request source station, relay station,... More Details >>
- No:22995
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:40
-
CC-Link master modules' start I/O No. and refresh devices RX/RY
The I/O numbers used for I/O modules and intelligent function modules cannot be used as refresh targets for RX/RY. Use the I/O numbers greater than those use... More Details >>
- No:22997
- Release Date:2018/09/03 17:31
-
Terminating resistors for RS-485 communication of LJ71C24
The resistance value is 110 ohm, 1/2 W. More Details >>
- No:22999
- Release Date:2018/09/03 17:31
- Update:2018/10/03 15:25
-
Executing the QJ71C24N's pre-defined protocol support function
Executing the CPRTCL instruction (dedicated instruction) executes a specified protocol. More Details >>
- No:23004
- Release Date:2018/09/03 17:31
-
Communication between a CC-Link master station and local stations
There are two modes of transient transmission, cyclic transmission and transient transmission, for the communication between a master station and a local sta... More Details >>
- No:23006
- Release Date:2018/09/03 17:31
- Update:2018/09/26 13:53
-
Connecting the CC-Link IE Field Network with a personal computer
To pursue high speeds, the CC-Link IE Field Network applies a communication control method different from that applied to the Ethernet communication for pers... More Details >>
- No:23012
- Release Date:2018/09/03 17:31
-
For CPU modules with 8192 I/O device points (X/Y0 to 1FFF), X/Y1000 and greater can be set as refresh devices. More Details >>
- No:23014
- Release Date:2018/09/03 17:31
-
Effect on sequence scans in MELSECNET/H networks
It is necessary to reduce the link refresh time of the MELSECNET/H network in order to reduce the scan time. The link refresh time can be reduced by reducin... More Details >>
- No:23018
- Release Date:2018/09/03 17:31
- Update:2018/09/26 09:27