FAQ


FAQAbout Products

- FAQ > Controllers > Programmable Controllers MELSEC > Network related products
FAQ
Keyword Search
FAQ within [ Network related products ]
-
Yes. More Details >>
- No:22998
- Release Date:2018/09/03 17:31
-
Terminating resistors for QJ71C24N
A terminating resistor must be connected to the interface in order to reduce signal reflections thus preventing the signal instabilities. More Details >>
- No:22982
- Release Date:2018/09/03 17:31
-
"[ ]" in the CC-Link remote I/O modules' model name "AJ65[ ]BT" represents as follows: - None: Standard type - S: Compact type - F: Low profile waterpro... More Details >>
- No:22974
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:12
-
Difference between AJ65SBTB1-16DT1 and AJ65SBTB1-16DT2
Major differences are shown below. - AJ65SBTB1-16DT1 - Rated input current approx. 5 mA - ON voltage/ON current 15 VDC or higher/3.0 mA or higher - O... More Details >>
- No:22972
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:04
-
Connecting terminating resistors for CC-Link communication
Connect terminating resistors to both ends of physical cables.A master station is not necessarily required to be connected to either end of its network. More Details >>
- No:23046
- Release Date:2018/09/03 17:31
-
Receiving back (echoing back) the same data sent from QJ71C24N
When data is sent from the RS-422/485 interface through RS-485 (2-wire type) communication and the same data comes back to RDA or RDB, we call it echo back. ... More Details >>
- No:23000
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:44
-
Identifying disconnected CC-Link stations
Identify disconnected stations using either of the following methods. (1) Select [Diagnostics] -> [CC-Link Diagnostics].from the menu in GX Works2 or G... More Details >>
- No:23053
- Release Date:2018/09/03 17:31
- Update:2018/09/26 10:59
-
RS-485 connection between LJ71C24 and an external device
Short between SDA and RDA and between SDB and RDB, and then connect them to + (Data-A) and - (Data-B) on the external device. More Details >>
- No:23048
- Release Date:2018/09/03 17:31
-
Limitation on the number of levels of cascade connections when QJ71E71-100 is used
If a repeater hub is used, 10BASE-T allows a maximum of four levels of cascade connections and 100BASE-TX allows a maximum of two levels of cascade connectio... More Details >>
- No:23040
- Release Date:2018/09/03 17:31
-
Unit of the receive data length used by the QJ71C24N series pre-defined protocol support function
The receive data length of the variable is specified in bytes. More Details >>
- No:23037
- Release Date:2018/09/03 17:31
11-20 of Total 110