SB/SW refresh device setting with CC-Link
There are no problems even though the SB/SW refresh device has not been set. More Details >>
- No:23080
- Release Date:2018/09/03 17:31
-
Using Ethernet UTP cables for the CC-Link IE Controller
Ethernet UTP cables cannot be used. More Details >>
- No:23062
- Release Date:2018/09/03 17:31
-
Setting required to skip CC-Link slave station numbers
A CC-Link slave station number can be skipped by assigning the skipped number to a reserved station. A reserved station is counted as one of all the connecte... More Details >>
- No:23029
- Release Date:2018/09/03 17:31
-
Clearing data in the QJ71C24N's receiving area buffer memory
Receiving data overwrites the buffer memory data. Writing 0 with a program can be performed but is unnecessary as the data is overwritten. More Details >>
- No:23009
- Release Date:2018/09/03 17:31
-
CC-Link master module settings
If each master module controls their own CC-Link networks, all master modules can be set as station 0 even though they are controlled by the same CPU. More Details >>
- No:23008
- Release Date:2018/09/03 17:31
-
Intelligent Buffer Select of the CC-Link parameter
Set the size of buffer memory used for transient transmission (by dedicated instructions) to local stations, the standby master station, and intelligent devi... More Details >>
- No:22977
- Release Date:2018/09/03 17:31
-
Limitation on the number of MELSOFT products that can be connected with the QJ71E71
In the TCP/IP connection, you can connect up to 17 MELSOFT products at the same time using a dedicated connection for system and the connections for users 1 ... More Details >>
- No:23063
- Release Date:2018/09/03 17:31
-
Cascade connections between hubs in the CC-Link IE Field Network
UP to 20 levels of cascade connections can be made. More Details >>
- No:23051
- Release Date:2018/09/03 17:31
- Update:2019/06/27 15:46
-
Connecting terminating resistors for CC-Link communication
Connect terminating resistors to both ends of physical cables.A master station is not necessarily required to be connected to either end of its network. More Details >>
- No:23046
- Release Date:2018/09/03 17:31
-
Station number settings for MELSECNET/H networks
A station number can be skipped by setting the station as a reserved station. More Details >>
- No:23045
- Release Date:2018/09/03 17:31