FAQ within [ Network related products ]
-
Difference between CC-Link reserved stations and invalid stations
- Reserved station Reserved stations are not actually connected to the network (but will be connected in the future) but do not appear as data link error... More Details >>
- No:22993
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:37
-
Mixing the CC-Link IE Field Network with general LAN communication
Mixed communication with the same hub cannot be established. Establish the CC-Link IE Field Network and general LAN communication separately. More Details >>
- No:22988
- Release Date:2018/09/03 17:31
- Update:2019/06/27 15:48
-
Terminating resistors for QJ71C24N
A terminating resistor must be connected to the interface in order to reduce signal reflections thus preventing the signal instabilities. More Details >>
- No:22982
- Release Date:2018/09/03 17:31
-
How refresh devices for CC-Link remote inputs and outputs are assigned
The refresh device setting of the CC-Link parameter assigns any devices to the I/O numbers greater than those assigned to the modules on the same base unit. ... More Details >>
- No:22968
- Release Date:2018/09/03 17:31
-
Terminating resistors for RS-422 communication of QJ71C24N
The resistance value is 330 ohm, 1/4 W. More Details >>
- No:22965
- Release Date:2018/09/03 17:31
- Update:2018/10/03 15:33
-
Parameter setting of CC-Link IE Field Network
No, you do not have to set the network range assignment parameters for slave stations. By setting the network range assignment parameters for a master statio... More Details >>
- No:23066
- Release Date:2018/09/03 17:31
-
Applicable size for plug-in connector socket block on QJ71C24N-R4
Use the plate terminal packaged with the module. The size of the plate terminal is 1.0 mm wide with a thickness of 0.8 mm. More Details >>
- No:23043
- Release Date:2018/09/03 17:31
-
Receiving data when no receive complete code is designated (QJ71C24N)
Data are received on a received data count basis. If there is no receive complete code and variable length data is received, the data is received at every no... More Details >>
- No:23038
- Release Date:2018/09/03 17:31
-
How to make the expanded cyclic setting for CC-Link local stations
Make the expanded cyclic setting for a CC-Link local station using the programming tool, GX Developer or GX Works2. Follow the procedure below. (1) Set th... More Details >>
- No:23030
- Release Date:2018/09/03 17:31
- Update:2018/09/26 10:17
-
CC-Link signals checked when an error occurs
Check the following signals.- Module error signal : X0- Host data link status signal: X1- Other station data link status signal: X3 More Details >>
- No:23021
- Release Date:2018/09/03 17:31