- FAQ > Controllers > Programmable Controllers MELSEC > Network related products
FAQ
Keyword Search
FAQ within [ Network related products ]
-
How to check the error history of the QJ71C24N with GX Developer
You can check the error history in the module detailed information in the system monitor of GX Developer. More Details >>
- No:23064
- Release Date:2018/09/03 17:31
-
Parameter setting of CC-Link IE Field Network
No, you do not have to set the network range assignment parameters for slave stations. By setting the network range assignment parameters for a master statio... More Details >>
- No:23066
- Release Date:2018/09/03 17:31
-
SB/SW refresh device setting with CC-Link
There are no problems even though the SB/SW refresh device has not been set. More Details >>
- No:23080
- Release Date:2018/09/03 17:31
-
Terminating resistors for RS-485 communication of LJ71C24
The resistance value is 110 ohm, 1/2 W. More Details >>
- No:22999
- Release Date:2018/09/03 17:31
- Update:2018/10/03 15:25
-
PLC parameter setting for QJ61BT11N
If the Network Parameter is used, CC-Link communication does not need the Select setting in the I/O assignment setting of the PLC parameter.If the parameter ... More Details >>
- No:23002
- Release Date:2018/09/03 17:31
-
Difference between networks called CC-Link and those called MELSEC
CC-Link IE, supported by the CC-Link Partner Association, is an open field network standard that integrates networks, from a controller network to field/moti... More Details >>
- No:23013
- Release Date:2018/09/03 17:31
-
Using a FROM/TO instruction after AJ71UC24 is replaced with QJ71C24N
I/O signals and buffer memory addresses need to be changed but data communications can be conducted using a FROM/TO instruction and X/Y signals. More Details >>
- No:23017
- Release Date:2018/09/03 17:31
-
Duplication error in a CC-Link master station
Possible causes are as follows.(1) Another master station exists on the same line.(2) Noise is detected on the line at power on. More Details >>
- No:23044
- Release Date:2018/09/03 17:31
-
Cascade connections between hubs in the CC-Link IE Field Network
UP to 20 levels of cascade connections can be made. More Details >>
- No:23051
- Release Date:2018/09/03 17:31
- Update:2019/06/27 15:46
-
Link register assignments in MELSECNET/10 networks
For any type of MELSECNET network (II, /10, and H), B and W devices with the same number cannot be used for multiple stations as write areas. Following th... More Details >>
- No:22971
- Release Date:2018/09/03 17:31
- Update:2018/09/25 13:24